58
Sensor Out-of-Order
If the Control Panel can’t receive
the signals transmitted from an
individual sensor over the preset
supervisory period, a Lost of signal
& sensor zone & name fault event
will be displayed on the screen
when you arm the system.
If the Control Panel does not
receive the signal, the system will
send report (code
147
) to the
Central Monitoring Station.
Sensor Restoration is also reported.
Interference
CTC-1241 will detect interference
only on the 868Mhz band.
When the system is programmed
with Interference Detection On, and
when there is an interference
detected for 30 seconds, the
Control Panel will report
Interference
(code
344
) to the
Central Monitoring Station.
4.16.5. Fault Message
Nomenclature
z
The fault event message is displayed in
short form as below:
Fault Condition
―
Message
displayed
Interference
―
Interference
AC Power Fail
―
AC failure
Control Panel low
battery
―
Panel L.B
.
Control Panel
sabotaged
―
Panel Tamper
Sensor Low Battery
―
(Sensor w/ Zone
Name) +
L.B.
Siren Low Battery
(Indoor/outdoor Siren)
+
L.B.
Sensor Sabotaged
―
(Sensor w/ Zone
Name) +
Tamper
Siren Sabotaged
(Indoor/outdoor Siren)
+
Tamper
Sensor out-of-order
―
(Sensor w/ Zone
Name) +
out
Siren out-of-order
(Indoor/outdoor Siren)
+
out
GSM out of Signal
―
GSM Signal
GSM module missing
―
GSM Missed
GSM Pin Code,
Incorrect/missing
―
GSM Pin Code
GSM locked by PUK
―
GSM PUK
SIM Card missing
―
SIM Card
<
<
E
E
X
X
A
A
M
M
P
P
L
L
E
E
>
>
If
DC Z 01 L.B.
is displayed, it means Zone
1 Door Contact is low battery.
<
<
N
N
O
O
T
T
E
E
>
>
)
While you arm the system, if any of
Door Contact or PIR is triggered,,
arming is also prohibited and the
sensor triggered will be displayed as
fault message.
Sensor triggered
Message displayed
Door Contact
triggered
(DC w/ Zone Name) +
open
PIR triggered
(IR w/ Zone Name) +
Active