18
2.3.3.11 Mobility
This function is designed to avoid an accident
(e.g. swoon or lost consciousness) happening
to the user without anyone notices. Under all
modes except Away arm mode, when the
system does not detect any user movement
within the pre-set mobility period, an inactivity
(alarm) report will be sent to the monitoring
center. The display will show Alarm! Alarm! and
the siren will sound.
z
Options available are
Disable
(no mobility
detecting),
4 Hours
,
8 Hours and 12
Hours.
o
D
i s a b
l e
4 H
o
u
r s
8 H
o
u
r s
1 2 H
o
u
r s
z
Disable
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
)
The mobility time resets once one of the
following conditions meet:
In
Home
mode: whenever any key of
Control Panel is pressed, or whenever
any
Home Omit / Day Home Omit /
Night Home Omit
DC or IR is
triggered within the pre-set Mobility
time period.
In
Day
Home
mode: whenever any
key of Control Panel is pressed, or
whenever any
Home Omit / Day
Home Omit
DC or IR is triggered
within the pre-set Mobility time period.
In
Night
Home
mode: whenever any
key of Control Panel is pressed, or
whenever any
Home Omit / Night
Home Omit
DC or IR is triggered
within the pre-set Mobility time period.
In
Alarm off
mode: whenever any of
the DC or IR (except
24 Hr, Fire,
Medical Emergency and Water
) is
triggered, or whenever any keys of the
Control Panel / RC / KP is pressed
within the pre-set Mobility time period.
)
The mobility function is disabled
automatically when the system is set to
Away Arm
.
2.3.3.12 Local Siren
This is used to program whether the Control
Panel raises local alarm while a sensor is
triggered.
o O n
O f f
z
On (Local Siren On)
is set as factory
default. When the Control Panel receives
an effectual triggered signal, its siren
raises alarm.
z
Off (Local Siren Off)
means when the
Control Panel receives an effectual
triggered signal, its siren will not raise
alarm. However, Water/Fire alarms are not
affected and Local Siren still emits alarm
sounds.
<
<
N
N
O
O
T
T
E
E
>
>
)
Whe Local Siren is set is OFF, the Bell Box
(BX) and Indoor Siren (SR) are not
affected and will emit an alarm sound.
2.3.3.13 Interference
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
)
This feature is only available for Area 1.
Changes made in Area 1 apply to both
Areas 1 & 2.
This is for you to decide whether the Control
Panel should detect signal jamming or not.
D e t e c t i o
n
O
n
o D e t e c t i o n O f f
z
Detection Off
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
)
When the
Detection On
is selected,
whenever the signal jamming period
lasted longer than 30 seconds, this
fault event will be logged, reported to
the Central Monitoring Station and
displayed on the LCD to warn the user.
)
When the
Dectection Off
is selected,
Control Panel will not check
interference status.