11
)
Four dots are displayed to indicate no
telephone number has been set.
<
<
E
E
X
X
A
A
M
M
P
P
L
L
E
E
>
>
)
acid1 Panel User 01 Area1 Cancel
acid1 = SMS Header
Panel = Device (Control Panel)
User 01 = User PIN code # 1
Area 1 = Area 1
Cancel = Fault/status (alarm cancelled)
)
acid1 DC Z01 Area 1 Low battery
acid 1 = SMS Header
DC = Device (Door Contact)
Z01 = Zone 1
Area 1 = Area 1
Low battery = Fault/status (low battery)
z
Change Tel. Numbers
Apply Steps 1-4 from
Store Tel. Numbers
section on the number that is wished to change.
New numbers will overwrite the previous one.
z
Delete Tel. Numbers
Step 1.
Apply Steps 1 & 2 from
Store Tel.
Numbers
section on the number that
is wished to delete.
Step 2.
Press
key to cancel the numbers.
Step 3.
Press
OK
and the previous stored
number is now deleted.
2.1.4. Back-Up Method
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
)
This feature is only required if any
phone numbers and/or IP address is
set as
Second Priority
reporting
source when they were programmed.
There are three reporting options to choose for
each back-up phone numbers and/or IP
address:
o B a c k - u p N o n e
B
a c k - u
p
1
B
a c k - u
p
2 v
(1) Back-up None (default):
The system will
not report to any second priority IP Address
nor phone number, unless all “
First
Priority
” IP address/phone number failed.
(2) Back up 1:
Rather than only report the
First Priority
IP addresses / phone
numbers, the system is also required to
report to one of the
Second Priority
IP
addresses / phone numbers before the
reporting terminates (with max of 5 retries).
(3) Back up 2:
Rather than only report the
First Priority
IP addresses / phone
numbers, the system is also required to
report to two of the
Second Priority
IP
addresses / phone numbers before the
reporting terminates (with max of 5 retries).
)
The Second Priority IP Address will be
reported in higher priority than Second
Priority Tel. Numbers.
2.1.5. Retry Method
Retry method is used to the reporting in
preferred sequenced/method.
O n e b y O
n
e
o A l t e r n a t I v e
z
One-by-One
If
One by one
method is chosen, the system
will try each IP Address or Phone to a max of 5
times before move on to the next priority.
<
<
N
N
O
O
T
T
E
E
>
>
)
An interval of report retry period is 8
secs.
)
When the Control Panel is connected
to the internet, IP reporting via internet
(IP) has higher priority than via GPRS.
z
If all set as first priority, calling sequences
will be:
IP/GPRS #1 1st time
Æ
…
Æ
IP/GPRS #1 5th
time
IP/GPRS #2 1st time
Æ
…
Æ
IP/GPRS #2 5th
time
TEL #1 1st time
Æ
…
Æ
TEL #1 5th time
TEL #2 1st time
Æ
…
Æ
TEL #2 5th time