20
2.3.3.17 Siren Delay
This is for you to decide how long should the
Control Panel suppress the audible alarms
after a Burglar or Entry alarm is reported.
Options are
Disable
and
1 Min
delay to
10 Min
delay in 1-Min increments.
o
D
i s a b
l e
1 M i n
.
.
.
1 0 M i n
z
Disable
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
)
Some audible alarms will not be
delayed (regardless of siren delay
setting) when the following conditions
are detected:
9
Fire alarm
9
Water alarm
9
Personal panic alarm
9
Medical emergency
9
Tamper alarm
9
GSM/GPRS failure
)
The alarm reporting will be sent
immediately, even if the audible alarm
is delayed.
2.3.3.18 Final Door
When the system is under away arming (see
section 4.2.1) with Final Door set to On and a
Door Contact set as Entry device, the system
will automatically full arm once the Door
Contact is detected as closed, even if the
count-down period is not yet complete.
o F i n a l d o o r O n
F i n a l d o o r O f f v
z
Final Door On
is set as factory default.
2.3.3.19 Verification
This is to set the Sequential Verification
Reporting.
o O n
O f f
z
On (Verification On)
is set as factory
default.
<
<
N
N
O
O
T
T
E
E
>
>
)
If there are more than one PIR motion
sensors or door contacts, whose
attributes are set as Burglar, with
Verification On
, when the first sensor
is triggered, the panel will report a
Burglar
alarm (event code 130) to the
central monitoring station.
)
If a second sensor is triggered again
within 30 minutes, the panel will report
another
Alarm confirm
(event code
139) to the central monitoring station.
)
If
Verification Off
is selected instead,
the panel will only send the first
Burglar alarm (event code 130) to the
central monitoring station.