3. Safety regulations 

10 

Refrain from any working method which is doubtful in 
terms of safety. 

Never play around with compressed air! 

Never aim compressed air at your skin or at other 
persons! 

Never use compressed air to clean your clothing. 

When using compressed air to clean equipment take 
the utmost care and always wear protective goggles. 

The compressed air generated by these compressors 
must never be used for breathing unless it has been 
conditioned for those applications in line with the “safety 
requirements for respiratory air”.  

Never use the machine in an environment where 
inflammable or poisonous vapour can be sucked in. 

Never operate the system at pressures and 
temperatures below or above the values indicated in 
the technical data sheet.  

The access panels, etc. have to be closed during 
operation.  

Check the machine/unit at least once per shift for visible 
damage and faults! Report any changes (including 
changes in the machine’s operating behaviour) to the 
responsible department/person immediately. If 
necessary, stop and lock the machine immediately!  

In the case of malfunction, stop the machine/unit 
immediately and lock it! Have any defects rectified 
immediately!  

Observe the start-up and stopping procedures and the 
control displays according to the operating instructions. 
Before starting up or setting the machine in motion, 
ensure that nobody is at risk.  

Do not cut off or remove extraction or venting facilities 
while the machine is running.  

3.5 

Special work/maintenance  

Carefulness  

Observe the adjusting, maintenance and inspection 
activities and intervals set out in the operating 
instructions, including information on the replacement of 
parts and equipment. These activities may be carried 
out by skilled personnel only.  

Brief the operating personnel prior to starting special 
operations or maintenance work! Appoint a person to 
supervise the activities!  

Maintenance and repair work may only be carried out 
under the supervision of a person who is qualified for 
this work.  

Oil losses result in a slippery floor. Therefore, always 
clean the floor and the outside of the machine prior to 
starting the maintenance work.  

Checks, maintenance and repair work may only be 
carried out with the screw compressor being at rest and 
depressurized. Protective equipment to be removed for 
this work, has to be refitted after completion of these 
activities. Operation of the machine without protective 
equipment is not permitted. When working on a running 
screw compressor system, working clothes have to be 
close-fitting.  

If the machine/unit is completely shut down for 
maintenance and repair work, it must be secured 
against inadvertent restarting:  

  Lock the main command elements and remove the 

key and/or  

  attach a warning sign to the main switch.  

Always use the correct tools for maintenance and repair 
work.  

Never use inflammable solvents or carbon tetrachloride 
to clean parts. Take precautions against poisonous 
vapours from cleaning agents.  

In any work concerning the operation, conversion or 
adjustment of the machine and its safety-oriented 
devices or any work related to maintenance, inspection 
and repair, always observe the start-up and shutdown 
procedures set out in the operating instructions and the 
information on maintenance work.  

Ensure that the maintenance area is adequately 
secured.  

To lower the risk of accidents, individual parts and large 
assemblies being moved for replacement purposes 
should be carefully attached to lifting tackle and secured. 
Use only suitable and technically correct lifting gear and 
only utilize suspension systems with adequate lifting 
capacity. Never work or stand under suspended loads!  

During maintenance and when carrying out repair work, 
cleanliness is very important. Avoid the ingress of dirt 
by covering parts and free openings with a clean cloth, 
paper or adhesive tape.  

After the completion of each repair, check that tooling 
or loose parts have not been left in the or on top of the 
machine, drive motor or drive equipment and ensure 
that no cloth has been left inside these units.  

Be careful when the screw compressor system is in 
operation.  

Maintenance/rectification of faults  

The employer has to inform the employee of the 
dangers possibly arising during the repair and 
maintenance of the machine/unit as well as on how to 
avoid them; the employee has to observe all measures 
for safety at work. Safety equipment for the prevention 
or elimination of danger has to be maintained regularly 
and functionally checked at least once a year. Faults 
observed have to be immediately rectified and/or 
reported to the responsible person.  

Summary of Contents for L07

Page 1: ...Original Operating and Service Manual Screw Air Compressor L07 L11 L07RS L11RS V2 GB CDN USA Id no CC1140579 00 March 2015...

Page 2: ......

Page 3: ...contact the local Gardner Denver Company or Distributor who is supplied with revised and up dated information In any communication concerning the compressor it is essential to quote the MODEL SERIAL...

Page 4: ...e Address ______________________________________________________________________________________ ______________________________________________________________________________________ ________________...

Page 5: ...n the operating manual and complying with the inspection and maintenance directives 1 3 Maintenance Carefully performed maintenance is imperative this ensures that your screw compressor can meet all t...

Page 6: ...ot be accepted in the case of Operating errors Incorrect maintenance Wrong auxiliary materials Use of spare parts other than Gardner Denver genuine spare parts Modifications and changes to the install...

Page 7: ...rt 23 5 2 Installation 24 6 Preparations for commissioning 25 6 1 Cooling air volume minimum cross 25 6 2 Compressed air connection 26 6 3 Electrical connection 27 6 3 1 Electrical connection USA CANA...

Page 8: ...lve 45 9 9 Changing V belts automatic tensioning system 46 9 10 Connecting terminals in the switch cabinet control transformer setting 46 9 11 Fittings 46 9 12 General maintenance and cleaning 47 9 13...

Page 9: ...sponsibility and duty of notification for taking into account in plant factors for example regarding work organization sequences of operations personnel assigned to certain tasks are to be added to th...

Page 10: ...well as to welding on structural or pressurized parts 3 4 Installation and normal operation Installation In addition to the general technical operation in accordance with the stipulations of the local...

Page 11: ...leaner cooler or warmer area via an intake channel depending on the size of the machine an additional fan could turn out to be necessary If the room temperature can fall below zero the condensation dr...

Page 12: ...out with the screw compressor being at rest and depressurized Protective equipment to be removed for this work has to be refitted after completion of these activities Operation of the machine without...

Page 13: ...be removed before these parts have cooled down to room temperature Check the accuracy of pressure and temperature indicators at regular intervals If the admissible tolerance limits have been exceeded...

Page 14: ...f this has been expressly authorized as there may be a risk of explosion and fire Before carrying out welding flame cutting and grinding operations clean the machine unit and its surroundings from dus...

Page 15: ...on Since corrosion occurs more quickly in damp atmospheres than in dry conditions it is not possible to specify a maximum permissible standstill time which will apply in all cases Note The following a...

Page 16: ...8 Symbols and explanations Carefully read the operating manual before commissioning or servicing this compressor Never breathe in compressed air from this system Never operate the unit with open door...

Page 17: ...3 Safety regulations 15 Warning Hot surface Warning Pressurized part or system Warning This system can start up by means of a remote control or automatically after a power failure...

Page 18: ...3 Safety regulations 16 Warning The system continues to run for 30 seconds after pressing the O key Warning Danger of electric shock Attention Lifting point...

Page 19: ...motor fasteners used for securing the unit during transportation have to be removed prior to commissioning see also chapter 6 4 Attention Danger of electric shock from loaded condensers Please always...

Page 20: ...l level indicator 11 Oil filter 12 Oil cooler 13 Safety valve 14 Pressure holding and check valve 15 Air cooler 16 Oil fine separator extractor 17 Oil temperature regulator 18 Cooling air ventilator 1...

Page 21: ...separator 8 Oil filler cap 9 Oil drain 10 Oil level indicator 11 Oil filter 12 Oil cooler 13 Safety valve 14 Pressure holding and check valve opening pressure 4 5 bar 15 Air cooler 16 Oil fine separa...

Page 22: ...he pressure reservoir at the same time 4 4 Air circuit The intake air passes through the intake filter 1 Fig 3 and the intake regulator 2 Fig 3 into the screw compressor 4 Fig 3 During the compression...

Page 23: ...e motor 3 Fig 4 starts up The compressor extracts a certain volume of air via a start valve 2 1 Fig 4 Pressure builds up in the reservoir and closes the regulator This way constant pressure of approx...

Page 24: ...lve Y1 Fig 4 is deenergized closed Reservoir pressure is reduced to approx 4 to 4 5 bar and the pressure maintenance valve 8 Fig 4 closes This way no more compressed air will be supplied to the mains...

Page 25: ...ifted load The proper lifting of the load according to the operating instructions of the load suspension device has to be ensured Important Never lift or lash the compressor and its hood via the enclo...

Page 26: ...have to be suitably identified and secured against touching See also the safety regulations in chapter 3 of the operating instructions Important The operator has to provide adequate ventilation for th...

Page 27: ...section of approx 0 2 m2 for L07 L11 Important The stated minimum cross section refers to a maximum duct length of 5 m 16 4 ft and a maximum of one bend In the event of differing values over 5 m 16 4...

Page 28: ...ecting hoses take appropriate measures to prevent whipping of the loose end in the event that the hose connection tears off Note After coolers separators collecting reservoirs and the compressed air l...

Page 29: ...a guide it is suggested that the ground wire be equal in size to one of the con ductors which feeds the compressor motor circuit Make certain the ground wire connections are clean and tight The wire u...

Page 30: ...efore touching the electrical components The power condensers require this time in order to discharge Important A wrong setting of the control power transformer jeopardizes the trouble free operation...

Page 31: ...portant Do not mix oils of different specifications Machines which are delivered without oil must first be filled to the max mark in the pressure reservoir sight glass see also chapters 9 4 and 9 15 C...

Page 32: ...ure level Sound pressure level measured in dB A according to PN8NTC 2 2 under full load at a distance of 1 m tolerance 3 dB A 60 Hz compressors dB A L07 71 L11 71 Speed controlled compressors 60 Hz dB...

Page 33: ...been switched on the POWER LOSS fault appears This fault must be acknowledged using the key Fig 16 You will find more information about the control in chapter 8 The factory setting of the setpoint val...

Page 34: ...be acknowledged using the key Fig 16 Press START button I Fig 16 To switch off the compressor in the usual way use the STOP button Fig 16 and not the emergency STOP button After shutdown the compress...

Page 35: ...ystem is fitted with a three row display 1st row The final compression temperature final compression pressure and network pressure are permanently displayed here Final compression temperature is the t...

Page 36: ...these keys at the same time until the right language appears 8 5 2 Setting network pressure apart from L07RS L11RS Max network pressure The network pressure is set in the CONTROL MENU sub menu The ke...

Page 37: ...the TARGET PRESSURE menu item Pressing the key causes the value to flash You can now correct increase or decrease this value using or Then confirm the value set by pressing the key 8 5 4 Setting time...

Page 38: ...ating instructions 8 9 1 Warning messages When there are warnings the red light signal flashes slowly The unit does not automatically shut down when there are warnings However ignored warnings may cau...

Page 39: ..._ 00 00 00 00 p27 ___________ 00 00 00 00 02 EM STOP 12345h 01 EM STOP 12300h CUT OUT POINT 13 0bar CUT IN POINT 12 5bar p2 CUT OUT POINT 10 5bar p2 CUT IN POINT 10 0bar AUTOMATIC OPERATION ENABLE REM...

Page 40: ...02 EM STOP 12345h 01 EM STOP 12300h CUT OUT POINT 13 0bar TARGET PRESSURE 12 5bar p2 CUT OUT POINT 10 5bar p2 TARGET PRESSURE 10 0bar AUTOMATIC OPERATION DISPLAY UNITS m3 min ENABLE REMOTE START OFF...

Page 41: ...he following points are observed Press the STOP button on the control panel and wait until the screw compressor unit has come to rest and the screw compressor unit is depressurized The pressure displa...

Page 42: ...or the kit part number and for the tool kit part number The tool kit is required to change the oil seal If the oil seal is a lip seal the wear sleeve must always be replaced 2 Replace lubricant every...

Page 43: ...9 Service and maintenance 41...

Page 44: ...ases When changing the oil the waste oil is to be drained completely since used oil reduces the service life of the new oil fill considerably Do not mix lubricating oils of different makes When changi...

Page 45: ...depressurized electrically isolate and locked off Wait at least 5 minutes for the oil to settle and for the air to disperse Unscrew the oil filter cartridge 1 Fig 18 using an appropriate tool Dispose...

Page 46: ...parator cartridge Check for leakage Check oil level see chapter 6 5 If required top up oil Changing intervals for oil fine separator cartridge The operating conditions e g coolant temperatures the ope...

Page 47: ...as SO2 solvent vapours etc have a strong influence on the service life of the filters air filters oil filters fine separators Where such conditions exist the filter element may require changing more f...

Page 48: ...out as follows Open front panel Lift the motor by turning the motion screw 2 Fig 22 counterclockwise until the V belts are released Clean degrease the V belt pulleys Replace the V belt set 5 Fig 22 Sc...

Page 49: ...essor system has been shut down and depressurized a Perform filter mat change as follows Remove mounting bolt 2 Fig 23 Remove filter mat 1 Fig 23 and clean exchange if damaged Re insert filter mat in...

Page 50: ...stationary compressors Lubricant recommendations Please note that proper lubrication will considerably increase the service life of your compressor unit According to regulations relating to the preve...

Page 51: ...reservoir 1 Fix intake regulator or if required replace check solenoid valves 2 Short circuit in the unit 2 Determine and eliminate cause replace defective fuses 3 Connecting terminals in the switch...

Page 52: ...n the compressed air 1 Oil fine separator defective 1 Replace oil fine separator cartridge 2 Oil foams 2 Change oil 3 Oil level too high 3 Drain off oil 4 Minimum pressure valve defective 4 Check mini...

Page 53: ...47 42 Full load current max 460V 575 V Amps 15 12 21 17 Motor protection type IP55 EPAct Nominal speed rpm 3600 Nominal fan motor power no separate fan motor Recommended cable size 200V 230V 460V 575...

Page 54: ...69 Nominal motor rating hp kW 10 7 5 Voltage frequency V 460V 10 60 Hz Full load current max at 460V Amps 18 Motor protection type TEFC IP55 EPAct Nominal speed rpm 1256 2950 Nominal fan motor power n...

Page 55: ...70 Nominal motor rating hp kW 15 11 Voltage frequency V 460V 10 60 Hz Full load current max at 460V Amps 24 Motor protection type TEFC IP55 EPAct Nominal speed rpm 1096 2950 Nominal fan motor power no...

Page 56: ...S Fig 24 all dimensions in mm A Compressed air connection G 3 4 B Cooling air inlet C Cooling air outlet D Cable entry E Cooling air outlet of control cabinet L07RS L11RS only F Cooling air inlet of c...

Page 57: ...55...

Page 58: ......

Page 59: ......

Page 60: ...essor Division 1800 Gardner Expressway Quincy Illinois 62305 Telephone 800 682 9868 Fax 217 224 7814 Gardner Denver Deutschland GmbH Argenthaler Str 11 55469 Simmern Deutschland Tel 49 0 6761 832 0 Fa...

Reviews: