8. Control system 

  

35 

8.5.3 Setting line pressure 

(only L07RS-L11RS) 

Speed is controlled with the aid of a PI controller 
implemented in the software and is matched  to the 
demand for compressed air. In the 

[

 

CONTROL

 

MENU

 

]

 

menu you have to set the maximum line pressure 
switching point (

CUT-OUT

 

POINT

) and the 

TARGET 

PRESSURE

When the maximum line pressure switching point is 
reached, the machine switches to off-load. 

In the range between 

TARGET PRESSURE

 and 

CUT-

OUT

 

POINT

 the speed of the machine is regulated 

according to the compressed air requirement.  

Example: 

CUT-OUT

 

POINT 10.0bar 

TARGET PRESSURE 

9.5bar 

The speed of the machine is regulated according to the 
need for compressed air so that the set pressure of 
9.5 bar is maintained. 

When the line pressure reaches 10.0 bar, the machine 
switches to off-load. 

Max. line pressure: 

The max. line pressure is set in the 

[

 

CONTROL

 

MENU

 

]

-

sub-menu. The 

  

+

 

 

 keys have to be pressed at the 

same time to do this. You are then taken to the main 
menu. Use 

 

  

 to switch to the 

[

 

CONTROL

 

MENU

 

]

 sub-

menu. Then please press the 

 key. 

 

The 

 CUT-OUT

 

POINT

 menu item now appears on the 

display. Again pressing the 

  key causes the value to 

flash. You can now correct (increase or decrease) this 
value using 

  

or

 

 

. Then confirm the value set by 

pressing the 

 key. 

 

Note  

The control system checks whether the value set can be 
used. The maximum line pressure 

 CUT-OUT

 

POINT 

must be at least 0.2 more than the 

TARGET

 

PRESSURE.

 

You may therefore have to first set the 

TARGET 

PRESSURE

. To prevent

 

your compressor suffering from 

excess wear, the difference between the 

CUT-OUT

 

POINT

 

and 

TARGET

 

PRESSURE 

should not be too small. 

Target pressure: 

In the 

 [

 

CONTROL

 

MENU

 

sub-menu please use 

 

 to 

go to the 

 TARGET PRESSURE

 menu item. 

Pressing the 

 key causes the value to flash.

 

You can now correct (increase or decrease) this value 
using 

  

or

 

 

. Then confirm the value set by pressing 

the 

 key. 

8.5.4 Setting time/date (timer) 

The GD PILOT accumulator can bridge a loss of power 
lasting between around two to three weeks. If power is 
lost for longer periods, the timer's time and date are lost 
and have to be entered anew. 

Press the 

  

+

 

 

 keys at the same time. Use 

 

 

 to go 

to the 

[

 

TIMER

 

CONTROL

 

sub-menu and press the 

 

key. The date and time are displayed there in the 
following format: 

TU 30.10.07 12:10:34 

If you press the 

 key, the left-hand value (day of the 

week) starts to flash. You can now use the 

  

or

 

 

 

keys to set this. Then confirm the value by pressing the 

 key.  

All values can now be set in succession using this 
procedure. When the last value (seconds) has been 
set, the timer is fully set and you can exit the menu by 
twice pressing the 

  

+

 

 

 keys at the same time. 

8.6 

Starting the unit 

 

Danger  

If the unit is ready, i.e. the green LED is flashing, 
the compressor may automatically start at any time.

 

Use the main switch to switch the unit on.  

If warning or fault messages appear in the third row of 
the display, these first have to be rectified and 
confirmed using the 

 key.  

Then start the unit by pressing the 

I

  key on the DELCOS. 

8.7 

Switching off the unit 

The unit is switched off by pressing the 

  key on the 

GD PILOT. However the unit will only stop after a 30-
second soft-stop. 

The soft-stop is preset to protect the compressor. 

 

Note  

The unit may only be shut down using the emergency 
off button in real emergencies. When shutting down 
normally, please use the 

  

key. 

 

8.8 

Emergency off button 

The emergency off button is situated next the GD 
PILOT. It is used to immediately shut down the unit. 
Only use the emergency off button to shut down the 
unit in emergencies. When shutting down normally, 
always use the 

  key. 

Summary of Contents for L07

Page 1: ...Original Operating and Service Manual Screw Air Compressor L07 L11 L07RS L11RS V2 GB CDN USA Id no CC1140579 00 March 2015...

Page 2: ......

Page 3: ...contact the local Gardner Denver Company or Distributor who is supplied with revised and up dated information In any communication concerning the compressor it is essential to quote the MODEL SERIAL...

Page 4: ...e Address ______________________________________________________________________________________ ______________________________________________________________________________________ ________________...

Page 5: ...n the operating manual and complying with the inspection and maintenance directives 1 3 Maintenance Carefully performed maintenance is imperative this ensures that your screw compressor can meet all t...

Page 6: ...ot be accepted in the case of Operating errors Incorrect maintenance Wrong auxiliary materials Use of spare parts other than Gardner Denver genuine spare parts Modifications and changes to the install...

Page 7: ...rt 23 5 2 Installation 24 6 Preparations for commissioning 25 6 1 Cooling air volume minimum cross 25 6 2 Compressed air connection 26 6 3 Electrical connection 27 6 3 1 Electrical connection USA CANA...

Page 8: ...lve 45 9 9 Changing V belts automatic tensioning system 46 9 10 Connecting terminals in the switch cabinet control transformer setting 46 9 11 Fittings 46 9 12 General maintenance and cleaning 47 9 13...

Page 9: ...sponsibility and duty of notification for taking into account in plant factors for example regarding work organization sequences of operations personnel assigned to certain tasks are to be added to th...

Page 10: ...well as to welding on structural or pressurized parts 3 4 Installation and normal operation Installation In addition to the general technical operation in accordance with the stipulations of the local...

Page 11: ...leaner cooler or warmer area via an intake channel depending on the size of the machine an additional fan could turn out to be necessary If the room temperature can fall below zero the condensation dr...

Page 12: ...out with the screw compressor being at rest and depressurized Protective equipment to be removed for this work has to be refitted after completion of these activities Operation of the machine without...

Page 13: ...be removed before these parts have cooled down to room temperature Check the accuracy of pressure and temperature indicators at regular intervals If the admissible tolerance limits have been exceeded...

Page 14: ...f this has been expressly authorized as there may be a risk of explosion and fire Before carrying out welding flame cutting and grinding operations clean the machine unit and its surroundings from dus...

Page 15: ...on Since corrosion occurs more quickly in damp atmospheres than in dry conditions it is not possible to specify a maximum permissible standstill time which will apply in all cases Note The following a...

Page 16: ...8 Symbols and explanations Carefully read the operating manual before commissioning or servicing this compressor Never breathe in compressed air from this system Never operate the unit with open door...

Page 17: ...3 Safety regulations 15 Warning Hot surface Warning Pressurized part or system Warning This system can start up by means of a remote control or automatically after a power failure...

Page 18: ...3 Safety regulations 16 Warning The system continues to run for 30 seconds after pressing the O key Warning Danger of electric shock Attention Lifting point...

Page 19: ...motor fasteners used for securing the unit during transportation have to be removed prior to commissioning see also chapter 6 4 Attention Danger of electric shock from loaded condensers Please always...

Page 20: ...l level indicator 11 Oil filter 12 Oil cooler 13 Safety valve 14 Pressure holding and check valve 15 Air cooler 16 Oil fine separator extractor 17 Oil temperature regulator 18 Cooling air ventilator 1...

Page 21: ...separator 8 Oil filler cap 9 Oil drain 10 Oil level indicator 11 Oil filter 12 Oil cooler 13 Safety valve 14 Pressure holding and check valve opening pressure 4 5 bar 15 Air cooler 16 Oil fine separa...

Page 22: ...he pressure reservoir at the same time 4 4 Air circuit The intake air passes through the intake filter 1 Fig 3 and the intake regulator 2 Fig 3 into the screw compressor 4 Fig 3 During the compression...

Page 23: ...e motor 3 Fig 4 starts up The compressor extracts a certain volume of air via a start valve 2 1 Fig 4 Pressure builds up in the reservoir and closes the regulator This way constant pressure of approx...

Page 24: ...lve Y1 Fig 4 is deenergized closed Reservoir pressure is reduced to approx 4 to 4 5 bar and the pressure maintenance valve 8 Fig 4 closes This way no more compressed air will be supplied to the mains...

Page 25: ...ifted load The proper lifting of the load according to the operating instructions of the load suspension device has to be ensured Important Never lift or lash the compressor and its hood via the enclo...

Page 26: ...have to be suitably identified and secured against touching See also the safety regulations in chapter 3 of the operating instructions Important The operator has to provide adequate ventilation for th...

Page 27: ...section of approx 0 2 m2 for L07 L11 Important The stated minimum cross section refers to a maximum duct length of 5 m 16 4 ft and a maximum of one bend In the event of differing values over 5 m 16 4...

Page 28: ...ecting hoses take appropriate measures to prevent whipping of the loose end in the event that the hose connection tears off Note After coolers separators collecting reservoirs and the compressed air l...

Page 29: ...a guide it is suggested that the ground wire be equal in size to one of the con ductors which feeds the compressor motor circuit Make certain the ground wire connections are clean and tight The wire u...

Page 30: ...efore touching the electrical components The power condensers require this time in order to discharge Important A wrong setting of the control power transformer jeopardizes the trouble free operation...

Page 31: ...portant Do not mix oils of different specifications Machines which are delivered without oil must first be filled to the max mark in the pressure reservoir sight glass see also chapters 9 4 and 9 15 C...

Page 32: ...ure level Sound pressure level measured in dB A according to PN8NTC 2 2 under full load at a distance of 1 m tolerance 3 dB A 60 Hz compressors dB A L07 71 L11 71 Speed controlled compressors 60 Hz dB...

Page 33: ...been switched on the POWER LOSS fault appears This fault must be acknowledged using the key Fig 16 You will find more information about the control in chapter 8 The factory setting of the setpoint val...

Page 34: ...be acknowledged using the key Fig 16 Press START button I Fig 16 To switch off the compressor in the usual way use the STOP button Fig 16 and not the emergency STOP button After shutdown the compress...

Page 35: ...ystem is fitted with a three row display 1st row The final compression temperature final compression pressure and network pressure are permanently displayed here Final compression temperature is the t...

Page 36: ...these keys at the same time until the right language appears 8 5 2 Setting network pressure apart from L07RS L11RS Max network pressure The network pressure is set in the CONTROL MENU sub menu The ke...

Page 37: ...the TARGET PRESSURE menu item Pressing the key causes the value to flash You can now correct increase or decrease this value using or Then confirm the value set by pressing the key 8 5 4 Setting time...

Page 38: ...ating instructions 8 9 1 Warning messages When there are warnings the red light signal flashes slowly The unit does not automatically shut down when there are warnings However ignored warnings may cau...

Page 39: ..._ 00 00 00 00 p27 ___________ 00 00 00 00 02 EM STOP 12345h 01 EM STOP 12300h CUT OUT POINT 13 0bar CUT IN POINT 12 5bar p2 CUT OUT POINT 10 5bar p2 CUT IN POINT 10 0bar AUTOMATIC OPERATION ENABLE REM...

Page 40: ...02 EM STOP 12345h 01 EM STOP 12300h CUT OUT POINT 13 0bar TARGET PRESSURE 12 5bar p2 CUT OUT POINT 10 5bar p2 TARGET PRESSURE 10 0bar AUTOMATIC OPERATION DISPLAY UNITS m3 min ENABLE REMOTE START OFF...

Page 41: ...he following points are observed Press the STOP button on the control panel and wait until the screw compressor unit has come to rest and the screw compressor unit is depressurized The pressure displa...

Page 42: ...or the kit part number and for the tool kit part number The tool kit is required to change the oil seal If the oil seal is a lip seal the wear sleeve must always be replaced 2 Replace lubricant every...

Page 43: ...9 Service and maintenance 41...

Page 44: ...ases When changing the oil the waste oil is to be drained completely since used oil reduces the service life of the new oil fill considerably Do not mix lubricating oils of different makes When changi...

Page 45: ...depressurized electrically isolate and locked off Wait at least 5 minutes for the oil to settle and for the air to disperse Unscrew the oil filter cartridge 1 Fig 18 using an appropriate tool Dispose...

Page 46: ...parator cartridge Check for leakage Check oil level see chapter 6 5 If required top up oil Changing intervals for oil fine separator cartridge The operating conditions e g coolant temperatures the ope...

Page 47: ...as SO2 solvent vapours etc have a strong influence on the service life of the filters air filters oil filters fine separators Where such conditions exist the filter element may require changing more f...

Page 48: ...out as follows Open front panel Lift the motor by turning the motion screw 2 Fig 22 counterclockwise until the V belts are released Clean degrease the V belt pulleys Replace the V belt set 5 Fig 22 Sc...

Page 49: ...essor system has been shut down and depressurized a Perform filter mat change as follows Remove mounting bolt 2 Fig 23 Remove filter mat 1 Fig 23 and clean exchange if damaged Re insert filter mat in...

Page 50: ...stationary compressors Lubricant recommendations Please note that proper lubrication will considerably increase the service life of your compressor unit According to regulations relating to the preve...

Page 51: ...reservoir 1 Fix intake regulator or if required replace check solenoid valves 2 Short circuit in the unit 2 Determine and eliminate cause replace defective fuses 3 Connecting terminals in the switch...

Page 52: ...n the compressed air 1 Oil fine separator defective 1 Replace oil fine separator cartridge 2 Oil foams 2 Change oil 3 Oil level too high 3 Drain off oil 4 Minimum pressure valve defective 4 Check mini...

Page 53: ...47 42 Full load current max 460V 575 V Amps 15 12 21 17 Motor protection type IP55 EPAct Nominal speed rpm 3600 Nominal fan motor power no separate fan motor Recommended cable size 200V 230V 460V 575...

Page 54: ...69 Nominal motor rating hp kW 10 7 5 Voltage frequency V 460V 10 60 Hz Full load current max at 460V Amps 18 Motor protection type TEFC IP55 EPAct Nominal speed rpm 1256 2950 Nominal fan motor power n...

Page 55: ...70 Nominal motor rating hp kW 15 11 Voltage frequency V 460V 10 60 Hz Full load current max at 460V Amps 24 Motor protection type TEFC IP55 EPAct Nominal speed rpm 1096 2950 Nominal fan motor power no...

Page 56: ...S Fig 24 all dimensions in mm A Compressed air connection G 3 4 B Cooling air inlet C Cooling air outlet D Cable entry E Cooling air outlet of control cabinet L07RS L11RS only F Cooling air inlet of c...

Page 57: ...55...

Page 58: ......

Page 59: ......

Page 60: ...essor Division 1800 Gardner Expressway Quincy Illinois 62305 Telephone 800 682 9868 Fax 217 224 7814 Gardner Denver Deutschland GmbH Argenthaler Str 11 55469 Simmern Deutschland Tel 49 0 6761 832 0 Fa...

Reviews: