13-18-607 Page 67
SECTION 9
MINIMUM PRESSURE/CHECK VALVE
MINIMUM PRESSURE/CHECK VALVE
- This device maintains minimum pressure within the air/oil
reservoir, thus insuring (cooling/lubricating) oil injection flow into the compressors. It also serves as a
check valve to prevent back flow of compressed air flow from the customer
’s piping or pipe network back
into the compressor package when the compressor is not active.
The valve does not require maintenance or (internal) adjustment. Refer to Part List 13-18-504 for spare
parts.
Before servicing the minimum pressure valve, always stop the unit, release air
pressure, lockout and tagout the power supply to the compressor package.
Failure to release pressure or properly disconnect the power may result in
personal injury or death.
NOTICE
Working spring within valve body is under tension. Failure to relieve spring
tension gradually may cause serious injury upon cap removal.
Minimum Pressure/Check Valve (MPV) Inspection:
1. Be sure the unit is completely off and that the oil sump is depressurized
– including pipe works
between MVP and (external) isolation valve.
2. Disconnect, lockout and tagout power supply to the compressor package.
3. Carefully and gradually unscrew the valve cap from the body
– this will also release tension from the
working spring within the valve. After cap removal, all internal parts can be retrieved
– note their
relative positions during disassembly to help the re-assembly process. See Fig 9-1, Page 63.
4. Re-assemble in reverse order.
Figure 9-1 – MINIMUM DISCHARGE PRESSURE/CHECK VALVE
Summary of Contents for AirSmart VS135A
Page 29: ...13 18 607 Page 28 Figure 4 2 PIPING AND INSTRUMENTATION ILLUSTRATION 305CGF797 A Ref Drawing...
Page 31: ...13 18 607 Page 30 300CGF546 D Ref Drawing Page 2 of 4...
Page 32: ...13 18 607 Page 31 300CGF546 D Ref Drawing Page 3 of 4...
Page 33: ...13 18 607 Page 32 300CGF546 D Ref Drawing Page 4 of 4...
Page 35: ...13 18 607 Page 34 302CGF546 E Ref Drawing Page 2 of 4...
Page 36: ...13 18 607 Page 35 302CGF546 E Ref Drawing Page 3 of 4...
Page 37: ...13 18 607 Page 36 302CGF546 E Ref Drawing Page 4 of 4...
Page 39: ...13 18 607 Page 38 303CGF546 C Ref Drawing Page 2 of 4...
Page 40: ...13 18 607 Page 39 303CGF546 C Ref Drawing Page 3 of 4...
Page 41: ...13 18 607 Page 40 303CGF546 C Ref Drawing Page 4 of 4...
Page 43: ...13 18 607 Page 42 305CGF546 C Ref Drawing Page 2 of 4...
Page 44: ...13 18 607 Page 43 305CGF546 C Ref Drawing Page 3 of 4...
Page 45: ...13 18 607 Page 44 305CGF546 C Ref Drawing Page 4 of 4...
Page 81: ......