13-18-607 Page 18
Before removing the oil filler plug, always stop the unit and release air
pressure, lockout and tagout the power supply to the compressor package.
Failure to release pressure or properly disconnect the power may result in
personal injury or death.
2.
Air Filter
- Inspect the air filters to be sure they are clean and the assembly is sealed tight. Refer to
Section 7, for complete servicing instructions. Be sure the inlet line is clean and sealed tight.
3.
Couplings
- Check setscrews for tightness. See Section 8.
4.
Piping
- Refer to Section 2,
“Installation,”
and make sure piping meets all recommendations.
5.
Electrical
- Check the wiring diagrams furnished with the unit to be sure it is properly wired. See
Figure 4-3 and Figure 4-4, pages 29 and 33, for general wiring diagrams and Section 2, for
installation instructions.
6.
Grounding
- Equipment must be properly grounded according to Gardner Denver Guidelines for
proper wiring, grounding and feed power conditioning.
Failure to properly ground the compressor package could result in controller
malfunction.
N
N
N
O
O
O
T
TT
I
II
C
C
C
E
E
E
Read the Operator’s Manual before operating the compressor.
7.
Rotation
- Check for correct rotation of all electric motors:
·
Use controller
“JOG MODE” to bump compressor motor. Proper rotation shall be
counterclockwise when facing the compressor shaft end.
·
Use controller
“JOG MODE” to bump heat exchanger cooling fan. Proper rotation shall be
clockwise when facing intake side of fan.
·
Use controller
“JOG MODE” to bump main motor cooling fan. Proper rotation is achieved when
cooling air is discharged over the main motor body or when fan rotation matches the indicated by
the arrow decal affixed to the fan hub, as viewed via the serrated cutout on the fan shroud. See
Figure 3-1 for details.
Summary of Contents for AirSmart VS135A
Page 29: ...13 18 607 Page 28 Figure 4 2 PIPING AND INSTRUMENTATION ILLUSTRATION 305CGF797 A Ref Drawing...
Page 31: ...13 18 607 Page 30 300CGF546 D Ref Drawing Page 2 of 4...
Page 32: ...13 18 607 Page 31 300CGF546 D Ref Drawing Page 3 of 4...
Page 33: ...13 18 607 Page 32 300CGF546 D Ref Drawing Page 4 of 4...
Page 35: ...13 18 607 Page 34 302CGF546 E Ref Drawing Page 2 of 4...
Page 36: ...13 18 607 Page 35 302CGF546 E Ref Drawing Page 3 of 4...
Page 37: ...13 18 607 Page 36 302CGF546 E Ref Drawing Page 4 of 4...
Page 39: ...13 18 607 Page 38 303CGF546 C Ref Drawing Page 2 of 4...
Page 40: ...13 18 607 Page 39 303CGF546 C Ref Drawing Page 3 of 4...
Page 41: ...13 18 607 Page 40 303CGF546 C Ref Drawing Page 4 of 4...
Page 43: ...13 18 607 Page 42 305CGF546 C Ref Drawing Page 2 of 4...
Page 44: ...13 18 607 Page 43 305CGF546 C Ref Drawing Page 3 of 4...
Page 45: ...13 18 607 Page 44 305CGF546 C Ref Drawing Page 4 of 4...
Page 81: ......