13-18-607 Page 21
buttons to move the cursor to other digits in the Target Pressure value. When the desired Target
Pressure value is displayed, press the Enter
button to save the new value. Pressing the
Stop/Reset
button will abort the change and restore the previous value.
In order to save the changes made to parameters, press the Stop/Reset button to go back to the
heading of the current menu and then press the Stop/Reset button again. If parameter changes
have been made, the following screen will appear.
To permanently save the changes that were made, press the Enter
button. If the
Stop/Reset button is pressed, the parameter changes will be lost the next time the compressor
power is turned off.
·
Setting the Unload and Load Pressure
After setting the Target Pressure, set the Unload and Load Pressures values in a similar fashion.
The Unload pressure is the third item in the Operation Adjustment sub-menu so press the Down
button to navigate to the Unload Pressure setting. The Unload Pressure will control at
which pressure the compressor unload and stops.
The Load pressure is the fourth item in the Operation Adjustment sub-menu so press the Down
button to navigate to the Load Pressure setting. The Load Pressure will control at which
pressure the compressor will startup again after unloading.
Operation at excessive discharge air pressure can cause personal injury or
damage to equipment. Do not adjust the full discharge air pressure above the
maximum stamped on the unit nameplate.
9.
Operating Mode
- Refer to Controller Manual 13-17-600 for more detailed information on the control
system.
10.
Enclosure
- Check for damaged panels or doors. Check all screws and latches for tightness. Be
sure doors are closed and latched.
OPERATION ADJUSTMENT
UNLOAD PRESSURE
110 PSI
(SELECT PARAMETER)
OPERATION ADJUSTMENT
LOAD PRESSURE
100 PSI
(SELECT PARAMETER)
STORE MODIFIED
PARAMETERS?
STOP = NO
ENTER = YES
Summary of Contents for AirSmart VS135A
Page 29: ...13 18 607 Page 28 Figure 4 2 PIPING AND INSTRUMENTATION ILLUSTRATION 305CGF797 A Ref Drawing...
Page 31: ...13 18 607 Page 30 300CGF546 D Ref Drawing Page 2 of 4...
Page 32: ...13 18 607 Page 31 300CGF546 D Ref Drawing Page 3 of 4...
Page 33: ...13 18 607 Page 32 300CGF546 D Ref Drawing Page 4 of 4...
Page 35: ...13 18 607 Page 34 302CGF546 E Ref Drawing Page 2 of 4...
Page 36: ...13 18 607 Page 35 302CGF546 E Ref Drawing Page 3 of 4...
Page 37: ...13 18 607 Page 36 302CGF546 E Ref Drawing Page 4 of 4...
Page 39: ...13 18 607 Page 38 303CGF546 C Ref Drawing Page 2 of 4...
Page 40: ...13 18 607 Page 39 303CGF546 C Ref Drawing Page 3 of 4...
Page 41: ...13 18 607 Page 40 303CGF546 C Ref Drawing Page 4 of 4...
Page 43: ...13 18 607 Page 42 305CGF546 C Ref Drawing Page 2 of 4...
Page 44: ...13 18 607 Page 43 305CGF546 C Ref Drawing Page 3 of 4...
Page 45: ...13 18 607 Page 44 305CGF546 C Ref Drawing Page 4 of 4...
Page 81: ......