13-18-607 Page 27
Blow Down Valve (P)
- This (two-way solenoid) device vents compressed air from the air/oil sump.
During compressor operation (e.g., compressors are running or they have temporarily stopped due to line
pressure reaching unload pressure); the blow down valve remains energized (closed) and the air/oil
reservoir remains pressurized. When compressor operation is halted (e.g., by use of the red
“STOP”
controller button, by loss of electrical energy, or by a shutdown condition), the valve is de-energized
(normally open state) and the air/oil reservoir is blown down.
Oil Flow Control Valve (U)
– This (normally open, two-way solenoid) device reduces the flow of injection
oil the compressor. Valve U is normally held open (de-energized) and is closed (energized) to reduce the
flow of injection oil to raise the discharge temperature of the compressor during operational conditions
such as cold ambient temperature or low package load levels.
Oil Flow Control Valve (V)
– This (normally open, two-way solenoid) device increases the flow of
injection oil the compressor. Valve V is normally held closed (energized) and is open (de-energized) to
increase the flow of injection oil during the start-up phase of package operation, thus allowing faster build-
up of compressed air in the sump.
Check Valve – Auxiliary Purge (Z) –
This device supplies air to the compressor inlet during operation
which requires the inlet valve to remain closed (e.g., unloaded running).
Air Filter Vacuum Switch (O) -
This device monitors the vacuum pressure at the discharge side of the
inlet air filter. When air filter vacuum reaches 30
” of water column, it triggers an air filter service
notification via the AirSmart controller.
Shuttle Valve (AA) –
This device allows fast operation of the Inlet Feed Valve (C) even when the sump is
depressurized.
Shaft Seal Drain Valve (X) –
This device allows the collection of oil bypassing the compressor shaft seal,
as well as its return into the compressor inlet. It is a 3-way solenoid valve which in its normally closed
state (de-energized), it allows the collection of shaft bypassed oil in a nylon tube connected to its exhaust
port. In its open state (energized), the valve drains the collection tube with a short blast of compressed
(air tapped from the dry-side of the oil sump) and routed to the compressor inlet. The valve is powered by
the AirSmart controller, via its built-in
“Drain Close/Open Intervals” logic usually dedicated to actuate the
condensate drain valve on the optional dryer modules. One (2) sec [open] interval and one (30) minute
[close] intervals are typically adequate to collect and drain shaft bypass oil - See AirSmart controller
manual 13-17-600 for further instructions.
Summary of Contents for AirSmart VS135A
Page 29: ...13 18 607 Page 28 Figure 4 2 PIPING AND INSTRUMENTATION ILLUSTRATION 305CGF797 A Ref Drawing...
Page 31: ...13 18 607 Page 30 300CGF546 D Ref Drawing Page 2 of 4...
Page 32: ...13 18 607 Page 31 300CGF546 D Ref Drawing Page 3 of 4...
Page 33: ...13 18 607 Page 32 300CGF546 D Ref Drawing Page 4 of 4...
Page 35: ...13 18 607 Page 34 302CGF546 E Ref Drawing Page 2 of 4...
Page 36: ...13 18 607 Page 35 302CGF546 E Ref Drawing Page 3 of 4...
Page 37: ...13 18 607 Page 36 302CGF546 E Ref Drawing Page 4 of 4...
Page 39: ...13 18 607 Page 38 303CGF546 C Ref Drawing Page 2 of 4...
Page 40: ...13 18 607 Page 39 303CGF546 C Ref Drawing Page 3 of 4...
Page 41: ...13 18 607 Page 40 303CGF546 C Ref Drawing Page 4 of 4...
Page 43: ...13 18 607 Page 42 305CGF546 C Ref Drawing Page 2 of 4...
Page 44: ...13 18 607 Page 43 305CGF546 C Ref Drawing Page 3 of 4...
Page 45: ...13 18 607 Page 44 305CGF546 C Ref Drawing Page 4 of 4...
Page 81: ......