3.1
CONNECTION TO GARDTEC
800 Series & 580
Connection to the Gardtec
800 Series (or Gardtec 580 via interface) is via the Speech
Dialler Serial Lead Part No 04-070. The plug end of the lead should be connected to the
Gardtec
800 Series SK3 (Digigard Communicator) (or PLG1 on the 580 interface) the
flying end should be connected to the dialler as shown below.
Dialler
Flying Lead
Function
Terminal
Core Colour
Panel to Dialler
FLT
Yellow
DIN to DOUT
TRG1
Green
DOUT to DIN
TRG2
Black
CLOCK
0V
Blue
0V
12V
Red
12V
Program Gardtec
800 Digicom Type option to Digigard.
Program Gardtec
800 PA Mode to Bells Always or Silent
When the Speech Dialler is connected to the Gardtec
800 Alarm activation will trigger
message 3, PA activation will trigger message 2 and channel 1 activation (as
programmed) will trigger message 1.
The link between 12V and Line fault on the Gardtec
800 must be removed.
3.2
CONNECTION TO OTHER EQUIPMENT
The dialler may be connected to any equipment that is able to give a positive or negative
output examples of this are given in Figs 2 to 5.
Fig 2.
1
2
3
4
5
6
7
8
NO
9
0
YES
FLT TRG1 TRG2 TRG3 TMP TMP 0V 12V
To L/F
Input
To Control
Panel
Tamper Loop
To Control
Panel 12V
Aux Supply
Fire PA
Alarm
Control Panel Outputs