background image

1.0

INTRODUCTION

The Gardiner Technology Gardtec Speech Dialler is intended for use as an automatic
message dialler. The primary use for the dialler is for connection to an alarm system
although the unit is flexible enough to have many other uses where the need for automatic
messages exists.

The dialler is fully programmable via an engineer code with limited programmable options
available to the user via a user code. Once programmed the unit will retain all
programmed settings (including speech), even in the event of a complete power down.

Up to four telephone numbers may be programmed into the dialler and call
acknowledgment may be programmed on or off

The unit may be used with the Gardtec 800 Series of control panels (or Gardtec 580 via an
interface) as a plug on unit, or hardwired to any other control panel that offers suitable
outputs. 

The dialler offers one common message (11 seconds duration) and up to three shorter
messages (3 seconds duration each). 

When connected to the Gardtec 800 Series or the Gardtec 580 (with interface) the dialler
is powered and activated via the serial communications link to the control panel. If
connected to other control equipment the dialler should be given a 12V d.c supply and is
triggered via three start input terminals, the start polarity of these terminals is fully
programmable.

Once triggered the dialler will dial the first telephone number, when the call is answered
the common message will be played followed by one of the three short messages
corresponding to alarm channels 1, 2 and 3 on the Gardtec (or inputs 1, 2 or 3 if controlled
by other equipment). If acknowledge is programmed off the dialler will terminate the call
after passing the message to the first telephone number , if no answer is obtained from
telephone number 1 the unit will sequentially move on to the next telephone numbers until
it is successful. 

If acknowledge is programmed to on, the unit will dial the telephone numbers in the same
way but the calls will require acknowledgement by the call recipient. The number of
acknowledged calls require to terminate the dialling sequence is fully programmable by the
user.

PR4100Rev1.7 SD.QXD  07/03/01  16:22  Page 4

Summary of Contents for GARDTEC SPEECH DIALLER

Page 1: ... G G G GA A A AR R R RD D D DT T T TE E E EC C C C S S S SP P P PE E E EE E E EC C C CH H H H D D D DI I I IA A A AL L L LL L L LE E E ER R R R Installation Programming Instructions PR4100Rev1 7 SD QXD 07 03 01 16 22 Page 1 ...

Page 2: ...PR4100Rev1 7 SD QXD 07 03 01 16 22 Page 2 ...

Page 3: ...ineer Options 5 1 Special Features 5 2 Initial Power Up 6 0 Programming 7 0 Telephone Numbers 7 1 Messages 7 2 User Code 7 3 Dial Attempts 7 4 Call Acknowledge 7 5 Engineer Code 7 7 Trigger Modes 7 8 Line Fault Monitor 7 9 Multi Trigger Inhibit 7 10 Serial Comms 7 11 FTC FS 7 12 Using the Dialler 8 0 Aborting Calls 8 1 Viewing Last Call Log 8 2 Error Messages 9 0 Guardian Guide 10 0 Engineers Appe...

Page 4: ...tec 800 Series or the Gardtec 580 with interface the dialler is powered and activated via the serial communications link to the control panel If connected to other control equipment the dialler should be given a 12V d c supply and is triggered via three start input terminals the start polarity of these terminals is fully programmable Once triggered the dialler will dial the first telephone number ...

Page 5: ... NS G 1234 J 00003 or otherwise approved for use with the Telephone Network It is essential that interconnection circuits should be such that the equipment continues to comply with the requirements of 4 2 of EN41003 for TNV Telephone Network Voltage circuits and 2 3 of EN60950 for SELV Safety Extra Low Voltage circuits after making connections between circuits 1 2 APPROVAL This apparatus has been ...

Page 6: ...efully hook the front cover onto the backplate at the top edge and with the cable through the aperture in the front cover snap the cover into place After wiring has been completed replace the front flap and the flap fixing screw Fig 1 3 0 TELEPHONE LINE CONNECTION The unit is supplied pre wired with a 3m length of telecom cable that is terminated with a standard BT type plug If this is to be conne...

Page 7: ...ype option to Digigard Program Gardtec 800 PA Mode to Bells Always or Silent When the Speech Dialler is connected to the Gardtec 800 Alarm activation will trigger message 3 PA activation will trigger message 2 and channel 1 activation as programmed will trigger message 1 The link between 12V and Line fault on the Gardtec 800 must be removed 3 2 CONNECTION TO OTHER EQUIPMENT The dialler may be conn...

Page 8: ...larm control panel Note Unit should be programmed for negative start 1 2 3 4 5 6 7 8 NO 9 0 YES FLT TRG1 TRG2 TRG3 TMP TMP 0V 12V 0V 12V To 12V Power Supply N O PA Button To Power Supply 0V Negative Trigger From Smoke Detector PR4100Rev1 7 SD QXD 07 03 01 16 22 Page 8 ...

Page 9: ...Note the use of a 6K8 pull up resistor across bell terminals Program Trigger Mode to Control Panel Trigger Program Multi Trigger Inhibit to ON 1 2 3 4 5 6 7 8 NO 9 0 YES FLT TRG1 TRG2 TRG3 TMP TMP 0V 12V BELL AZx AZx TAMP AUX N C PA LOOP N C FIRE LOOP 6K8 PR4100Rev1 7 SD QXD 07 03 01 16 22 Page 9 ...

Page 10: ...wered the common message will be played followed by message No 3 The start polarity of the trigger terminals is programmable to Ve or Ve Recommended use of the trigger terminals would be as follows TRG1 Common Message1 Fire message TRG2 Common Message 2 PA Message TRG 3 Common Message 3 Intruder Message TMP TB3 SELV Two TMP terminals are provided These terminals are connected to the cover flap tam...

Page 11: ... Messages Common message When the dialler is triggered and the call is answered the dialler will pass this common message followed by the short message corresponding to the trigger input Speech for this common message may be up to 11 seconds duration a typical message would be This is John Atherton 5 High Street Newtown this is a Short Message 1 This message corresponds to a trigger 1 input and wi...

Page 12: ...ledge may be programmed to 0 1 2 3 or 4 If 0 is programmed the dialler will see when it has passed a message to the recipient and the dialler will then shut down If programmed to 1 2 3 or 4 the dialler will give a tone after the message has been passed this tone then has to be acknowledged by the recipient by pressing the key for 1 second the tone will be repeated and will need to be acknowledged ...

Page 13: ...be triggered by a positive signal 3 Control Panel trigger this mode allows the dialler to be triggered directly from the zone inputs and bell output of the Gardtec 350 or Gardtec 580 without interface see Fig4 When used in this mode the Multi Trigger Inhibit option should also be turned ON The default trigger polarity is negative trigger Line Monitor Security Mode This option allows the security o...

Page 14: ... option is ON clear by user code 5 2 SPECIAL FEATURES Three Way Call Feature In the event that the dialler is being used on a shared line and the telephone line is engaged by an incoming call the dialler will detect that the telephone is ringing and when triggered will park the incoming call obtain a new line and then continue with the dialling sequence In order for this desirable feature to opera...

Page 15: ...of the factory default reset modes may be used see engineers appendix 2 When the eight seconds has expired the display will show For up to one minute During this period the dialler is running a self calibration routine After the calibration routine has finished the display will show one of the following The on display shows the unit is turned on and is ready for a trigger the oF display shows the ...

Page 16: ... should be noted If programming has been accessed via the User code no access is available to program the engineer code or any options that appear under the engineer menus P4 Display Shows or Enter User or Engineer Code followed by YES Enter Menu Number required YES YES YES YES PR4100Rev1 7 SD QXD 07 03 01 16 22 Page 16 ...

Page 17: ... messages may be Listened to Deleted or Programmed Options available in the options Menu are 1 Change User Code See Section 7 3 2 Change Dial Attempts See section 7 4 3 Change Call Acknowledge See section 7 5 Note Engineer has no option to change User Code Options available in the Engineer Menu are 1 For future use 2 Change Engineer Code See section 7 7 3 Change Trigger Mode See section 7 8 4 Line...

Page 18: ...elete the existing Telephone Number 5 Pressing YES will delete the number and return to step 1 or 6 Pressing NO will flash The existing telephone Number may now be re programmed 7 Enter the required number whilst the number is being entered pressing NO will abort to step 1 without updating the number After the number has been entered press YES The dialler will now return to step1 8 Other numbers m...

Page 19: ... the message then return to step 1 or 4 Press YES to delete or program the message not applicable to options 5 6 or 7 The display will flash This is asking if you wish to delete the existing message 5 Pressing YES will delete the message and return to step 1 or 6 Pressing NO will allow the existing message to be re programmed If NO has been pressed the display will show 7 At this display you shoul...

Page 20: ...at the user code may only be re programmed if the programming mode has been accessed using the user code Enter the Options menu refer to section 7 0 1 With the display showing 2 Enter 1 followed by YES The display will flash 3 Enter your new four digit code followed by YES If NO is pressed during code entry the code will not be updated The dialler will now return to step 1 4 Pressing 0 once will r...

Page 21: ...turn to the oF or on state 7 5 PROGRAMMING CALL ACKNOWLEDGE Enter the options Menu refer to section 7 0 1 With the display showing 2 Enter 3 If NO is pressed the current number of call acknowledgments required will be shown and the dialler will return to step 1 or If YES is pressed the current number of call acknowledgments required will be displayed this may be changed by using the 1 2 3 or 4 key...

Page 22: ... will return to the P display or twice will return to the oF or on state 7 8 PROGRAMMING TRIGGER MODE No access is available to this option via the user code it may only be accessed via the engineer code Enter the engineers Menu refer to section 7 0 1 With the display showing 2 Enter 3 If NO is pressed the current Trigger Mode will be displayed and the and the dialler will return to step 1 or If Y...

Page 23: ...is programmed to ON 7 9 PROGRAMMING LINEFAULT MONITOR No access is available to this option via the user code it may only be accessed via the engineer code Enter the engineers Menu refer to section 7 0 1 With the display showing 2 Enter 4 If NO is pressed the current Linefault Monitor voltage will be displayed and the dialler will return to step 1 or If YES is pressed the current Linefault Monitor...

Page 24: ...ing 2 Enter 5 If NO is pressed the current Multi Trigger Inhibit state will be displayed and the dialler will return to step 1 or If YES is pressed the current Multi Trigger Inhibit state will be displayed Press NO to change the Multi Trigger Inhibit to one of the following Multi Trigger Inhibit is ON Multi Trigger Inhibit is OFF When you are satisfied with the Multi Trigger mode shown press YES a...

Page 25: ...pressed the current Serial Comms mode will be displayed Press NO to change the Serial Comms to one of the following Serial Comms ON Serial Comms OFF When you are satisfied with the Serial Comms mode shown press YES and the dialler will return to step 1 3 Pressing 0 once will return to the P display or twice will return to the on or oF state Note Serial Comms should only be programmed ON when the d...

Page 26: ...e state will be displayed and the dialler will return to step 1 or If YES is pressed the current FTC Clear by Code state will be displayed Press NO to change the Serial Comms to one of the following Clear by Code ON Clear by Code OFF When you are satisfied with the mode shown press YES and the dialler will return to step 1 3 Pressing 0 once will return to the P display or twice will return to the ...

Page 27: ... turn the dialler OFF enter the user code 5678 default followed by NO The display will show 8 1 ABORTING CALLS Calls from the dialler may be aborted if they have been triggered accidentally To abort a call enter the code factory default 5678 Provided the dialler has not started to play the speech message the display will show For three seconds If this display does not show then either a The dialle...

Page 28: ... return to its original state 9 0 ERROR MESSAGES The following messages may appear on the display Bad Checksum A bad checksum has been returned the dialler will reboot and attempt to recalibrate Poor Lock A poor lock has occurred with the Phase Lock Loop The dialler will reboot and attempt to recalibrate No Lock No lock has occurred for the Phase Lock Lock Loop The dialler will reboot and attempt ...

Page 29: ...aller has failed to pass the speech message s this may be due to a line fault being present as the dialler was attempting to dial The display may be cleared by either a successful communication or entering the user code dependant on the status of the FTC FS clear by user code option see 7 12 Alarm The call was aborted after the message had started to play The last call log may be used to determine...

Page 30: ... pass the common message containing the name and address of the caller followed by one or more short message s containing the type of alarm g Fire P A Burglar 3 If call acknowledge has been programmed OFF the unit will then close down or go on to dial other Guardians as programmed or If call acknowledge has been programmed ON the dialler will give a tone after the messages have passed this tone sh...

Page 31: ... Common Message Unprogrammed Short Message 1 to 3 Unprogrammed User Code 5678 Dial Attempts 3 Call acknowledge 1 Engineer Code 1234 Trigger Polarity ve Line Monitor Low 4V Multi Trigger Inhibit Off Serial Comms Off FTC Fail to Speak Clear by User Code On PR4100Rev1 7 SD QXD 07 03 01 16 22 Page 31 ...

Page 32: ...power to the unit 3 Whilst 88 is displayed the first 8 seconds Press 4 6 YES NO 4 The unit will return all programmed settings to factory defaults and re calibrate this may take up to one minute Reset Mode 2 1 Remove all power from the Gardtec Speech Dialler for at least five seconds 2 Re apply power to the unit 3 Whilst 88 is displayed the first 8 seconds Press 1 9 YES NO 4 The unit will return u...

Page 33: ...ill be displayed as a P on the display both whilst pro gramming and viewing the telephone numbers This feature allows the Speech Dialler to be used with many common switchboards 12 2 PAGER OPTIONS Five new options have been added to the User Menu P3 section 7 0 these are Option No Feature Description 1 Unchanged N A 2 Unchanged N A 3 Unchanged N A 4 Set Pager to Tel No Allows any of the four telep...

Page 34: ...Pager Number e g Tel No 1 2 3 or 4 If the display flashes for example t1 the number is not currently allocated as a Pager Number pressing YES will allocate it and the display will stop flashing If the display shows for example t1 without flashing the number is already allocated as a Pager Number pressing NO will deselect it and the display will flash Repeat this step for all Telephone Numbers you ...

Page 35: ... display the current message type or go to step 14 to skip this option The display will show for example 13 Choose from 1 Send only the Message to the Pager if programmed 2 Send only the Site Code if programmed 3 Send Both if programmed Enter your required Digit followed by YES The display will show 14 To program the Pager Make press 8 followed by YES pressing NO will display the current Pager Mak...

Page 36: ...Number 16 Digits if no Site Code is used 13 Digits if Site Code is used Note It is important that the Call Acknowledgement and Number of Dial Attempt features are fully understood Please refer to sections 5 0 7 4 7 5 The Pager feature does not decrement the Call Acknowledgments For example if the Pager is the first Telephone Number and a relative is the second and Call Acknowledgement is set to 1 ...

Page 37: ...PR4100Rev1 7 SD QXD 07 03 01 16 22 Page 37 ...

Page 38: ...TQ United Kingdom Tel 01706 510000 Fax 01706 510100 International Tel 44 1706 510000 International Fax 44 1706 510100 Technical Support Tel 01706 510200 Technical Support Fax 01706 510204 Mon Fri 0900 1730 PR4100 Rev1 7 PR4100Rev1 7 SD QXD 07 03 01 16 22 Page 38 ...

Reviews: