7.11
PROGRAMMING SERIAL COMMS
No access is available to this option via the user code, it may only be accessed via
the engineer code.
Enter the engineers Menu (refer to section 7.0)
1)
With the display showing:-
2)
Enter 6. If NO is pressed the current Serial Comms state
will be displayed and the dialler will return to step 1.
or
If YES is pressed the current Serial Comms mode will be
displayed. Press NO to change the Serial Comms to one
of the following:-
Serial Comms ON
Serial Comms OFF
When you are satisfied with the Serial Comms mode shown
press YES and the dialler will return to step 1.
3)
Pressing 0 once will return to the 'P' display or twice will return
to the 'on' or 'oF' state.
Note:
Serial Comms should only be programmed ON when the dialler is being
used with the Gardtec 800 Series or the Gardtec 580 with Digigard interface.
PR4100Rev1.7 SD.QXD 07/03/01 16:22 Page 25