background image

When connecting the pump to the water supply 

system, the country-specific sanitary regula-

tions must be observed to prevent water not of 

drinking water quality being drawn back in.

 DANGER! Electric shock!

The pump must not be used when people are  

in water.
Make sure that the electrical plug and socket 

connections are fitted in an area which cannot 

be flooded.
Protect the power plug from moisture.

 DANGER! Electric shock!

With a cut off mains plug, moisture can get into 

electrical parts via the mains cable and cause  

a short circuit.
Do not cut the mains plug off (e. g. to feed 

through a wall).
Do not use the power cable for plugging off.

v  

If the supply cord is damaged, it must be 

replaced by the manufacturer, its service 

agent or similarly qualified persons in order  

to avoid a hazard.

Extension cables
Data indicated on the type plate must match 

the technical data of the mains supply.
Following DIN VDE 0620 the power cable as 

well as any extension cable must not have  

a smaller diameter than rubber sheathed cables 

described with letter symbols H07 RNF.

v  

If the supply cord is damaged, it must be 

replaced by the manufacturer, its service  

agent or similarly qualified persons in order  

to avoid a hazard.

Protect the power cable from heat, oil and 

sharp edges.

 Do not use the power cable for carrying the 

pump or for unplugging.

In Austria
In Austria the electrical connection must satisfy 

the ÖVE-EM 42, T2 (2000)/1979 § 22 to § 

2022.1. This requires that pumps used for 

swimming pools and garden ponds may only be 

powered through an isolating trans former.

v

 Please ask your electrician for his advice.

In Switzerland
In Switzerland portable devices that are used 

 outdoors must be connected through a residu-

al-current device.

General Information

DANGER!

 Scalding from hot water!

The water can get very hot during operation 

(particularly if only small quantities are 

drawn).

v  

Before carrying out any work on the 

pump, allow it to cool down (for at least 

30 minutes).

Visual check

v  

Before operating the pump, first make  

a visual check to ensure there is no damage  

to the pump (especially regarding power  

cable and plug).

A damaged pump must not be used.

  In case of damage, please have the pump 

checked by our GARDENA Service Centre  

or by an  authorised electrician.

Safety in operation
Protect the pump from rain. Do not use  

the pump in a wet or moist area.
In order to avoid dry-running of the pump,  

take care that the end of the suction hose is 

always submerged into the water.

v

  Before each operation, fill the pump to 

 overflowing with approx. 2 to 3 l of water  

to be pumped!

Very fine sand can pass through the inte-

grated filter (mesh size 0.45 mm) and cause 

accelerated wear in the hydraulic parts.

v  

For sandy water, you should additionally use 

the GARDENA pump pre-filter, art. no. 1730 

(mesh size 0.1 mm).

Please ensure that no unauthorised persons  

or children are within reach of the pump and  

the pumped medium without supervision.
When using the pump for domestic water 

 supply, please adhere to the local water and 

sewerage regulations. In addition observe  

the regulations of DIN 1988.

 If necessary, contact your local water 

 authority.

DANGER! This product makes an electromag-

netic field while it operates. This field may under 

16

EN

Summary of Contents for Comfort 4000/5E

Page 1: ...tomatico ES Instrucciones de empleo Estaci n de bombeo PT Manual de instru es Bomba de press o PL Instrukcja obs ugi Hydrofor HU Haszn lati utas t s H ztart si automata szivatty CS N vod k obsluze Dom...

Page 2: ...the pump pressure have to be added together Example pressure at the tap 2 0 bar maximum pressure of the Electronic Pressure Pump 3500 4E 3 5 bar total pressure 5 5 bar Liquids pumped The GARDENA Elect...

Page 3: ...powered through an isolating trans former v Please ask your electrician for his advice In Switzerland In Switzerland portable devices that are used outdoors must be connected through a residu al curr...

Page 4: ...e is automatically reset to normal operation of the Electronic Pressure Pump and allows a trouble free use of the washing machine for 60 minutes Info LED The pump is equipped with a faults diagnostics...

Page 5: ...n the connection fit tings with the upmost care Use sealing tape only for sealing metallic connection fittings Suction inlet Art 1723 Art 1724 4 3 2 Do not use any water hose snap connection system co...

Page 6: ...the liquid to be pumped via the filler connection 0 up to the overflow approx 2 to 3 l until the water level no longer drops under the suction side inlet or the water flows out at the horizontal conne...

Page 7: ...the Electronic Pressure Pump must be emptied and stored where it will not become frozen Store out of the reach of children 1 Change the switch q to O 2 Unplug the mains connection for the pump 3 Open...

Page 8: ...t no 1758 2 Disconnect mains plug 3 If necessary close all valves on the intake side 4 Open all pressure side outlets so that the pressure side is depressurised Afterwards close the tapping points aga...

Page 9: ...ault Indicator is deleted by switching off the pump or pulling the mains plug Problem Possible Cause Remedy Info LED blinks once During the initial operation the pump did not suck water for 30 seconds...

Page 10: ...cuit breaker activated motor overheated v Allow the pump to cool down for 20 minutes Info LED blinks 3 times During the current operation the pump has extracted no water for 30 seconds Water supply di...

Page 11: ...GARDENA Service Switch is not turned to I v Restart the pump see 4 Operation Mains plug not plugged in v Insert mains plug into a mains socket 230 V AC Power failure v Check fuse and cables Free the i...

Page 12: ...For vacuum resistant connection of the pump to boreholes or pipe networks Length 0 5 m With 33 3 mm G1 female thread at both ends Art no 1729 GARDENA Connection Set Connection Set for 1 2 Pressure Ho...

Page 13: ...ollowing provisions The product was used for its intended purpose as per the recommendations in the operating instructions Neither the purchaser nor a third party has attempted to repair the product T...

Page 14: ...i ikke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale G...

Page 15: ...javljujemo kako ne prihva amo nikakvu odgovornost za o te enja na na im proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekori tenja or...

Page 16: ...acima est o em conformidade com as diretrizes uniformizadas da UE os padr es de seguran a da UE e os padr es espec ficos do produto Este certificado deixa de ser v lido se as unidades forem modificada...

Page 17: ...anduiding M rknings r CE M rknings r CE merkin kiinnitysvuosi Anno di applicazione della certificazione CE Colocaci n del distintivo CE Ano de marca o pela CE Rok nadania oznakowania CE CE jelz s elhe...

Page 18: ...Szivatty jellegg rbe Charakteristika erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba karakteri...

Page 19: ...S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku To...

Reviews: