1. Turn the filter
(7)
1/4 turn clockwise and remove it (bayonet lock).
2. Clean the filter
(7)
under running water.
3. Re-install the filter
(7)
in the opposite sequence.
The pump must not be operated without the filter.
To flush the pump:
After pumping chlorinated water, the pump must be flushed.
1. Pump lukewarm water (max. 35 °C), possibly adding a mild cleaning
agent (e. g. detergent) until the pumped water runs clear.
2. Remove residuals according to the waste disposal laws applicable in
your area.
5. STORAGE
To put into storage:
The pump is not frost-proof!
The product must be stored away from children.
1. Disconnect the pump from the mains.
2. Turn the pump upside down until no more water runs out.
3. Clean the pump (see 4. MAINTENANCE).
4. Store the pump in a dry, enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v
Dispose of the product through or via your municipal recycling
collection centre.
6. TROUBLESHOOTING
DANGER! Risk of injury!
Injury when the product starts accidentally.
v
Disconnect the product from the mains before you trouble-
shoot the product.
Problem
Possible Cause
Remedy
Pump is running,
but doesn’t deliver
Air cannot escape, because the
pressure line is closed. (Pos-
sible kink in the pressure hose.)
v
Open the pressure line
(e. g. shut-off valve, delivery
units).
Air in suction foot.
v
Wait for about 60 seconds
until the pump has vented;
if necessary, turn off and then
on again.
Filter is clogged.
v
Clean the filter
(see 4. MAINTENANCE).
Water level below minimum
water level when put into
operation.
v
Submerge the pump deeper.
When using the floating
suction, an air cushion
forms in the suction hose.
v
Remove the non-return valve
in front of the filter basket of
the extraction unit.
Pump does not start,
or stops suddenly during
operation
Thermal switch has turned the
pump off because of overheat-
ing.
v
Clean the filter
(see 4. MAINTENANCE).
Observe the max. media
Temperature (35 °C).
Check valve is stuck.
v
Contact the GARDENA
Service.
Pumping without electricity.
v
Check fuses and electrical
plug connections.
RCD has triggered
(residual current).
v
Disconnect the pump
and contact the GARDENA
Service.
Only with Art. 1771 / 1773:
Leakage warning is activated.
The maximum duration of the
leakage warning (low quantity
program 60 min. or 2 min.)
has been exceeded.
v
When using the low quantity
programme, shorten the
watering duration or interrupt
for 5 minutes. Increase the
water consumption. Discon-
nect the mains plug.
Leak on pressure side.
v
Eliminate any leak on the
pressure side.
Problem
Possible Cause
Remedy
Pump is running,
but the delivery drops
Filter is clogged.
v
Clean the filter
(see 4. MAINTENANCE).
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
7. TECHNICAL DATA
Submersible Pressure
Pump
Unit
Value
(Art. 1768)
Value
(Art. 1771)
Value
(Art. 1773)
Rated Power
W
900
900
1100
Mains voltage
V (AC)
230
230
230
Mains frequency
Hz
50
50
50
Max. delivery capacity
l/h
5900
5900
6100
Max. pressure /
max. delivery head
bar /
m
3,5 /
35
3,5 /
35
4,7 /
47
Max. submersion depth
m
12
12
17
Residual water level
mm
15
15
15
Switch-on pressure
bar
–
2,2
2,9
Min. submersion depth
for operation (approx.)
mm
100
100
100
Power cable
m
15 (H07RN-F)
15 (H07RN-F)
20 (H07RN-F)
Weight without cable
(approx.)
kg
7,5
7,5
8,1
Fastening rope length
m
15
15
20
Max. media temperature
°C
35
35
35
8. ACCESSORIES
GARDENA Floating suction
system
For dirt-free suction below the water surface.
Art. 1417
GARDENA 2- / 4-Way Valve
For parallel connection for more than one hose
or connected devices.
Art. 1210 / 1194
GARDENA Hose Clamp
For 25 mm (1") hoses via the connection nipple.
Art. 7192
GARDENA Hose Clamp
For 19 mm (3/4") hoses via the connection
nipple.
Art. 7191
GARDENA Pump Connection
Set
For 13 mm (1/2") hoses via the GARDENA
Connection System.
Art. 1750
GARDENA Tap Connector
GARDENA Hose Connector
For 16 mm (5/8") hoses via the GARDENA
Connection System.
Art. 18202
Art. 18216
GARDENA Pump
Connection Set
For 19 mm (3/4") hoses via the GARDENA
Connection System.
Art. 1752
9. SERVICE / WARRANTY
Service:
Please contact the address on the back page.
Warranty statement:
In the event of a warranty claim, no charge is levied to you for the services
provided.
GARDENA Manufacturing GmbH grants a warranty for all original
GARDENA new products for two years from the date of original purchase
from the retailer, provided that the devices have been for private use only.
This manufacturer’s warranty does not apply to products acquired second
hand. This warranty includes all significant defects of the product that can
be proved to be material or manufacturing faults. This war ranty is fulfilled
by supplying a fully functional replacement product or by repairing the
faulty product sent to us free of charge; we reserve the right to choose
between these options. This service is subject to the following provisions:
• The product has been used for its intended purpose as per the
recommendations in the operating instructions.
• Neither the purchaser nor a third party has attempted to open or
repair the product.
• Only Original GARDENA replacement parts and wear parts have been
used for operation.
• Presentation of the receipt.
Normal wear and tear of parts and components (such as blades, blade
fixing parts, turbines, light bulbs, V-belts / toothed belts, impellers, air
EN
10
1768-20.960.01.indd 10
23.09.19 15:26