background image

Rev.18/04/2013 

FUN installation 

Please note that housing heater must be connected only to 
appropriate power supply sources as previously indicated in this 
manual. 
All outdoor GH-F housings are provided with a power distribution 
board; if you need to install a GH-B12 fun, you need to substitute 
this board with the once coming with the fun and you must provide 
a stabilized (12VDC

  

 ±5%) power supply source.

 

Follow these steps: 
1. 

Open the housing like above indicated. 

2. 

Connect fun  “JP1”terminal to  AUX terminals of distribution 
power supply board 

3. 

connect  the camera power conductors to “OUTPUT” 
terminals of distribution power supply board. 

4. 

Connect the main power supply input conductors to 
appropriate “INPUT” terminals of distribution power board. 

5. 

Connect “HEATER” terminals of distribution power board to 
heater power supply conductors. 

6. 

Fix the fun board on spacers located on upper part of the 
housing.  

In case you have not bought a pre-cabled version of GH-F housing, 
the  power supply line have to be provided by a three conductors 
cable running through the central PG11 gland inside of the housing 
or by the appropriate rubber provided for hidden cabling running 
(see Hidden cable protection connection): the main power supply 
conductors have to be connected to the appropriate terminal strips 
in the following way:  

Meaning 

Conductors color         Terminal strip

 

MainPower IN                      Blue/Brown                     INPUT 
Out Heater 

White 

        HEATER 

Out Camera 

 

 

        OUTPUT 

Out Fun 

 

 

AUX 

 

In addition, crimp the ground conductor to a ring terminal and fix it 
to the point identified by Ground symbol by the M4 screw provided 
on standard distribution board.  

 
In case of 12VDC

 

  models, use pin n°1 as 

po12V) and pin n°2 as negative (0V). 

 

 

ZVA-TW100T/GH installation (only 230V~ versions) 

Please note that housing heater must be connected only to 
appropriate power supply sources as previously indicated in this 
manual. 
Follow these steps: 
1. 

Open the housing like above indicated.  

2. 

Connect “AUX” terminals of distribution power supply board 
to the ZVA-TW100T/GH “230V~” terminals 

3. 

connect the camera power conductors to “OUTPUT” 
terminals of distribution power supply board in parallel. 

4. 

Execute all remaining connections following indications of 
ZVA-TW100T/GH manual. 

5. 

Connect the main power supply input conductors to 
appropriate “INPUT” terminals of distribution power board. 

6. 

Fix the board on spacers located  on bottom part of the 
housing.  

In case you have not bought a pre-cabled version of GH-F housing, 
the power supply line have to be provided by a three conductors 
cable running through the central PG11 gland inside of the housing 
or by the appropriate rubber provided for hidden cabling running 
(see Hidden cable protection connection): the main power supply 
conductors have to be connected to the appropriate terminal strips 
in the following way:  

Meaning 

Conductors color         Terminal strip

 

MainPower IN                      Blue/Brown                     INPUT 
Out Heater 

White 

        HEATER 

Out Camera 

 

 

        OUTPUT 

ZVA-TW100T/GH 

 

AUX 

 

In addition, crimp the ground conductor to a ring terminal and fix it 
to the point identified by Ground symbol by the M4 screw provided 
on standard distribution board.  

GH-VTA installation 

This device does not need any additional power supply; please fit 
tamper and GH-VTA-T into their appropriate  bays located in back 
part of the housing (see FIG.5).   

External connections 

In case you have not bought a pre-cabled version of GH-F housing, 
you will need to run a RG-59/U cable through one of the side 
glands PG9, crimp it and connect to the camera. Verify the proper 
water seal of the gland.   
In case you need auxiliary connection cabling with camera station 
(for example motorized zoom, tamper sensors, camera serial port), 
run a multiconductors cable by one of the PG9 gland inside of the 
housing. 
Note that to open the PG shape, you need to force it using a screw 
driver from outside part of the housing (see FIG.6) 

Hidden cable protection connection  

Also easy hidden cable protection is available following four quick 
steps (see FIG.8): 
1. 

force the hidden cabling shape, in the middle of the 
housing, with a screw driver from outside part of the 
housing. 

2. 

properly fix bracket to the wall after having inserted cables 

3. 

run cables inside adjustable head and fix it to the bracket 

4. 

Insert cables in conic rubber, please note that only two 
halls are opened by default and that you need to open the 
third one in case you want to use additional cables. 

5. 

fix housing on adjustable head only with provided screws 

6. 

rubber will be automatically pressed on housing body 
guaranteeing IP66 protection.    

Please use only appropriate cables. 

 

ENCLOSURE ASSEMBLY 

Housing re-assembly 

If this will be the latest operation to complete the housing body 
closure, insert the desiccant bag (without plastic protection) inside 
of the body before to proceed. 
Close top body of the housing and fix it by the two opened swivel 
spindles. Please turn the two safety screws for 90° matching locker 
symbol and taking care that no cables are improperly running out 
the housing. 
Please assure all cables are correctly running inside the housing 
before to close it and to not force housing to be closed.  

Sunshield adjust 

Sunshield can be moved to different positions unscrewing it. Please 
note that you can find two additional shapes in the internal part of 
the sunshield that you can drill to achieve an additional sunshield 
excursion (see FIG.8). 
 

Fixing of sunshield 

Re-positioning of the sunshield on the holding points. 
Insert the fixing screws and tie. 

NOTES:

  every time you will open the housing, to avoid any 

condensation effect, please change the desiccant bag with 
a new one. 

 

FIXING THE CAMERA STATION 

The GH-F housing series is a light and medium/small enclosure for 
CCTV camera/lens outdoor application. Nevertheless, especially 
outdoor application can face severe environmental condition like 
strong wind, heavy snow and ice in addition to a suitable load 
bearing. 
This require to the installer the maximum and careful attention on 
fixing the camera station in the proper and safety way. 
For example, to fix a camera station using GH-F  housing series 
with its own adjustable head and bracket on a wall, we suggest you 
to use (4) steel fasteners with 12 mm external diameter and M6 bolt 
with 10mm head. 
Use as drilling mask a photocopy 1:1 of the latest page of this 
manual reporting the bracket and cable running holes layout 
positioning. 

NOTES 

 

GH-F housing provides two frontal screw threads for easy and 
comfortable accessories installation (ex.  IR lamps) and an 
additional round shape that could be used for additional hidden 
cabling or installation of air-filter (see FIG.9).  

 

In case you need lateral bracket cabling, you can operate as 
indicated in FIG.10. 

 

Use only neoprene outdoor cables to guarantee IP66 
protection rate: Video RG59 Ø6,1 mm, Alimentation  Ø7 mm 
(3x1 mmq)  

 

Lock safely high voltage cables and properly separate them by 
low voltage ones 

 

When used/requested, cut ground cable longer than phase and 
neutral  

 

This housing must not be considered a FIRE-ENCLOSURE; all 
installed equipments must be compliant to EN 60950-1.  

 

PLEASE DO NOT CLEAN FRONTAL WINDOW WITH ANY 
CHEMICAL PRODUCT; PLEASE USE ONLY WATER  

 
TECHNICAL SPECIFICATIONS 

Consumption: 
 

GH-F230:  

< 40 mA 

 

GH-F24: 

< 350 mA 

 

GH-F12: 

< 700 mA 

Maximum internal load:  

20W (-20°C ~50°C) 

IPrate:  

 

IP 66 (hidden or external cabling) 

Operating Temperature: 

-20°C to +55°C (Max.internal load 17W) 

Storage Temperature: 

-30°C to +55°C, RH 85% not 
condensing 

Vandal resistance: 

IK10 according to EN50102 

Fire-self extinguish:  

V2 fire-self extinguish according 
to UL94 

Summary of Contents for GH-F12

Page 1: ...protection GH FW12concavi apassaggiointerno preassemblati GH FW12 vormontiert mit verstecktem Kabelschutz GH FW12 pr mont avec protection de c ble dissimul e Kompletna obudowa GH FW12 obudowa z ukryt...

Page 2: ...2 Rev 18 04 2013 FIG 1 90 FIG 2 FIG 3 FIG 4 FIG 5 FIG 6 FIG 8 FIG 9...

Page 3: ...67180 www cbc de com CBC EUROPE GmbH 7 8 Garrick Industrial Centre Irwing Way GB London NW9 6AQ Tel 44 0 208 732 3312 Fax 44 0 208 202 3387 www cbceurope com CBC Poland Sp zo o Ul G Morcinka 5 Paw6 01...

Page 4: ...e four polycarbonate screws locking the four swivel spindles The top part of the housing can be pivoted on both sides alternatively or completely removed operating by the special swivel spindles pleas...

Page 5: ...erial port run a multiconductors cable by one of the PG9 gland inside of the housing Note that to open the PG shape you need to force it using a screw driver from outside part of the housing see FIG 6...

Page 6: ...aprire la custodia necessario ruotare di 90 almeno 2 viti di blocco prima agire sulle maniglie della custodia La parte superiore della custodia pu essere rimossa completamente aprendo tutte le manigl...

Page 7: ...apposito incavo garantendo una tenuta IP66 Utilizzare solo cavi conformi alle richieste CHIUSURA ED ASSEMBLAGGIO Chiusura custodia Se questa l ultima parte del corpo custodia che ne consentir il compl...

Page 8: ...schl sse entsichert und ge ffnet werden siehe Abb 1 WARNUNG Die Unterseite des Geh uses nimmt die Schaltung f r die Spannungsversorgung und die Anschlussklemmen auf an denen Netzspannung anliegt Schal...

Page 9: ...Kabelschutzanschluss kann mit vier schnellen Schritten vorgenommen werden siehe Abb 8 1 ffnen Sie in der Mitte des Geh uses das vorgestanzte Loch f r die versteckte Verkabelung mit einem Schraubendreh...

Page 10: ...que Les triers de fermeture permettent de soulever la partie sup rieure du caisson des deux c t s ou de la retirer compl tement pour retirer la partie sup rieure du caisson d verrouiller et ouvrir tou...

Page 11: ...er un tournevis sur l ext rieur du caisson pour l ouverture du trou pr perfor pourle vissage voirfig 6 Raccordement dissimul delaprotection de c ble M me un raccordement de protection de c ble dissimu...

Page 12: ...taj c ze specjalnych trzpieni obrotowych Aby ca kowicie zdj g rn cz obudowy nale y odblokowa i otworzy wszystkietrzpienie patrzRys 1 OSTRZE ENIE Ty korpusu obudowy zawiera obwody zasilaj ce i z cze li...

Page 13: ...y u y rubokr ta naciskaj c nim od zewn trznej strony obudowy patrz Rys 6 Ukrycie przewod w w uchwycie W czterech szybkich krokachmo na wykona tak e atwo ukrytei zabezpieczone po czeniekablowe 1 Udro n...

Page 14: ...istro de circuitos en conexcion de alimentaciones de energia de altos voltajes Antes de abrir la carcasa favor de apagar la linea principal de la alimentacion Por razones de seguridad reglamentarios l...

Page 15: ...ificacion corran un conducto de multitud de cables atravez por una de las glandula PG9 adentro de la carcasa Nota para abrir la figura PG se va requerir que forzar con un desarmador de parte de afuera...

Page 16: ...GH F24 housing sunshield heater 24V GH F230 housing sunshield heater 230V GH FW12 housing sunshield heater 12VDC GH WFM GH FW24 housing sunshield heater 24V GH WFM GH FW230 housing sunshield heater 23...

Page 17: ...17 Rev 18 04 2013...

Page 18: ...18 Rev 18 04 2013...

Page 19: ...19 Rev 18 04 2013...

Page 20: ...20 Rev 18 04 2013...

Reviews: