IDL 101
COMMUNICATION
HB_IDL101_E_V222.doc
81
Gantner Instruments Test & Measurement GmbH
ADR ..................... IDL 101 address (
hex 00..7F)
FNR ..................... function number (
hex 10)
REGSTA ................ address of the first register to be written
REGNUM ............... number of registers to be written
BYTNUM ............... number of databytes (max. 64)
D0 - Dn ................ databytes (max. 64)
CRC
..................... check
sum
CRC polynomial: u
15
+ u
13
+ 1
CRC start value:
hex FFFF
10.4.4. Register Contents
Register Type
Content
Range
variable values in integer format
0000 ............. ro/rw .............variable 1 .........integer value.......... -32768 ... 32767
0001 ............. ro/rw .............variable 2 .........integer value.......... -32768 ... 32767
:
:
:
:
0007 ............. ro/rw .............variable 8 .........integer value.......... -32768 ... 32767
:
:
:
:
001F ............. ro/rw .............variable 32........ integer value......... -32768 ... 32767
Register Type
Content
Range
read and write variable (real format)
0020 ............. ro/rw .............variable 1 real value high word......................0 ... 65535
0021 ............. ro/rw .............variable 1 real value low word .......................0 ... 65535
0022 ............. ro/rw .............variable 2 real value high word......................0 ... 65535
0023 ............. ro/rw .............variable 2 real value low word .......................0 ... 65535
:
:
:
:
002E ............. ro/rw .............variable 8 real value high word............................0 ... 65535
002F ............. ro/rw .............variable 8 real value low word.............................0 ... 65535
:
:
:
:
005E ............. ro/rw .............variable 32 real value high word..........................0 ... 65535
005F ............. ro/rw .............variable 32 real value low word...........................0 ... 65535
Attention
: The low word and the high word of a variable always have to be read or written simultaneously.
Notice
: The possibility of a writing command on the registers 0000 up to 002F depends on the configuration. With the
following variable types a writing command is valid if this has been allowed by the
Configuration Software ICP 100.
Digital Counter with Reset Function:
After a writing command for this variable the counter will be set to zero.
Arithmetic Variable with min/max-Function and Reset Function:
After a writing command for this variable the pull-pointer will be reset.