GL7p - Battery-powered, door-mounted electronic locker lock GL7p
Operation
64
HB_GL7p--EN_12
www.gantner.com
► Unlock the door. Depending on the type of lock (data carrier or PIN code), press the GL7p button in with a valid
data carrier or enter a valid PIN code when the door is locked.
o
The locker door unlocks and must open without resistance. If the door or latch jams, re-adjust the door
or latch (see below).
o
If the data carrier was not read, the RFID reading field may be misaligned and the range too small. In
this case, recalibrate the reading field by reading the SERVICE data carrier (see "6.5.6. SERVICE
Data Carrier").
► Check that the latch is firmly seated on the mounting thread.
Adjusting the locker door and door latch
If a
problem, as described previously in “Instructions”, occurs while opening or closing the locker door during
functional testing:
► Adjust the position of the locker door using the dimensions in sections “3.8 Installation of the GL7p” and "8.9
► If the door does not adjust properly, mount it in a different position.
► If the door is damaged, replace the door with a new door.
► Ensure that the correct latch is installed so that it sits exactly against the stop on the locker wall when the door
closed and keeps the door closed without any play. See
sections “3.8 Installation of the GL7p” and "8.9
► If the supplied standard latch does not suit the locker wall (e.g., when retrofitting), a corresponding offset latch
can be ordered. The standard latch must not be bent or modified in any way.
► If the latch is damaged, it must be replaced.
7.4 Disposal
-
Do not dispose of the GL7p and the associated components with the normal household waste, but
rather at your local electronic waste recycling facility in accordance with European Directive
2002/96/EC.
-
Recycle defective or used batteries according to European Directive 2006/66/EC.
-
Observe local regulations for the separate disposal of batteries.
-