GL7p - Battery-powered, door-mounted electronic locker lock GL7p
Configuration
46
HB_GL7p--EN_12
www.gantner.com
5.4.7
MASTER Data Carriers
Up to 10 MASTER data carriers (also called MASTER cards) can be assigned to the GL7p to allow the locker to be
opened in special circumstances, e.g., when a user has lost their data carrier. For this functionality, the MASTER data
carriers must be first entered, which is done here:
Configuration > Application > Master cards > MasterCard1 - 10
► Enter the number of each MASTER data carrier into the respective fields.
NOTE!
The MASTER data carrier numbers must be entered in hexadecimal format.
There is also an OPEN MASTER data carrier available (not included in the Basic Set). This special data carrier
can be used like the MASTER data carriers to open all lockers; however, it cannot lock the lockers. It is
possible to program an OPEN MASTER data carrier by entering the number of the OPEN MASTER data
carrier into 1 of the 10 fields. In this case, only 9 MASTER data carriers can be used.
5.4.8
Wireless Interface
For GL7p variants with a wireless interface (variants GL7p.
2
xxx and GL7p.
3
xxx), the identification can also be
transmitted wirelessly, e.g., via smartphone. The wireless interface can be enabled via the following option.
Configuration > Application > Reader > BLE > General > BLE enabled
► Select the option if you want to use the wireless interface.
► You can configure the wireless interface as required via the other fields in this window.
5.4.9
PIN-Code Keypad
For GL7p variants with a PIN-code keypad (variants GL7p.
1
xxx and GL7p.
3
xxx), the identification can also be
completed using a PIN code. To allow entry via PIN code, the following option must be enabled.
Configuration > Application > Reader > KeyPad > General > KeyPad enabled
► Select the option if you want to use the PIN-code keypad.
► Via the other fields in this window, you can specify the time within which a PIN code must be entered and set
the permitted length of the PIN code.