GL7p - Battery-powered, door-mounted electronic locker lock GL7p
Configuration
www.gantner.com
HB_GL7p--EN_12
37
5
CONFIGURATION
RF exposure statement
The users must keep at least 20 cm separation distance from the device, except during the identification and
operation process at the device (e.g. PIN-code input), which must be performed as described in this manual.
5.1 General Information
The GL7p is configured using a PC/laptop and GAT Config Manager software or with the MoLA app on a mobile
device. The configuration file must only be uploaded to the lock once. The configuration file of the first lock in the
system is saved in GAT Config Manager after which the file is uploaded to each lock that requires the same
configuration. Locks that require a different configuration need a separate configuration file to be made in GAT
Config Manager.
The MoLA app can be downloaded from the Google Play Store and used with mobile devices with an Android
operating system. The app uses NFC for configuration, which means that the mobile device must also support NFC
communication. See more details in section "5.3. Configuration with the MoLA App".
NOTE!
After importing the configuration file to the first lock, complete an operational test to ensure the user and
MASTER data carriers and the general lock functionality perform as expected.
The following data is imported into the GL7p during configuration:
-
Site key
-
Sub-site number
-
Locker number
-
Lock operating mode (“free locker”, “free locker universal”, “free locker unique number”, “personal locker
programming card”, or “personal locker expiry date”. See section “6.3. Operating Modes”)
-
Free locker: Sector number of the data on the data carrier and the time setting for the "duration of use"
function
-
Date and time
-
Unique numbers of the MASTER data carriers (and OPEN MASTER data carriers, if used)
The MASTER data carriers and OPEN MASTER data carriers can also be directly programmed into the GL7p
(see section
“6.5.1 MASTER
”). However, the most efficient way to program the data carrier numbers
into multiple locks is via PC and GAT Config Manager.
NOTE!
The GL7p does not set the daylight-saving time automatically. Time changes due to daylight saving must be
considered when evaluating bookings and also when authorizing data carriers with expiry dates/times!
5.2 Configuration with GAT Config Manager
5.2.1
Setup for Configuration in GAT Config Manager
Once the GL7p is connected to the computer via the USB cable (see
“4.3. USB Connection”), and the SERVICE
data carrier used to activate configuration mode (see "6.5.6 SERVICE Data Carrier"), the settings can be viewed
and configured using GAT Config Manager.