GL7p - Battery-powered, door-mounted electronic locker lock GL7p
Operation
54
HB_GL7p--EN_12
www.gantner.com
Locking and unlocking lockers with a data carrier
► Close the locker door.
► Press the button of the GL7p in using a data carrier for approximately 1 second.
o
The information on the data carrier is read.
a) Valid data carrier: The LED flashes blue briefly and then green and the action (lock/unlock) is carried out.
The time on the data carrier is checked and the current time written onto the data carrier.
b) Invalid data carrier: The LED flashes blue briefly and then red and the GL7p switches off without completing
the locking action. Possible reasons for this include:
- Another locker has already been locked using the data carrier. In this case, the first locker must be
unlocked before the data carrier can be used with the new locker.
- The duration of use period has been exceeded and the locker cannot be opened anymore. In this case,
the data carrier must be reset at a central station.
► When locking the locker, check that it is locked by pulling the locker door.
6.3.2
Free Locker Universal Mode
The
“Free locker universal” operating mode differs from the standard free locker mode in the following ways:
- Free locker universal mode allows the use of data carriers that are also used for other applications.
- No validity date with free locker universal mode.
- It is not possible to use a duration of use time with free locker universal mode.
- The following requirements for the data carriers apply:
1. The locker segment must be unused and "empty", i.e., coded with all zeros.
2. The Access Keys must be correct.
Locking and unlocking lockers with a data carrier
► Close the locker door.
► Press the button of the GL7p in using a data carrier for approximately 1 second.
o
The information on the data carrier is read.
a) Valid data carrier: The LED flashes blue briefly and then green and the action (lock/unlock) is carried out.
b) Invalid data carrier: The LED flashes blue briefly and then red and the GL7p switches off without completing
the locking action.
► When locking the locker, check that it is locked by pulling the locker door.
Locking and unlocking lockers with a PIN code
► Close the locker door.
► Enter your PIN code.
NOTE: The length of the PIN code can be defined in the configuration.
► Press the OK button (
✓
) or the button of the GL7p to confirm the PIN code.
o
The PIN code is checked.
a) Valid PIN code: The LED flashes green briefly and the action (lock/unlock) is carried out.
b) Invalid PIN code: The LED flashes red briefly and the GL7p switches off without completing the locking
action.