 INSTALLATION MANUAL PAGE 1

WARNING

Fixtures must be installed by a qualified electrician in accordance with all applicable national and local electrical 
and construction codes and regulations. Please read through this entire document before beginning the 
installation.

Remove any fixture from service if water or corrosion is observed inside the fixture.  Water and chemicals can 
corrode metallic components and damage electrical circuits. Faulted electrical circuits can experience self-
heating which, while unlikely, may present a fire hazard if left unchecked. This heating can also serve as an 
ignition source for gasses generated by the corrosion of metals inside of the enclosure. Regularly scheduled 
inspections are recommended to ensure safe operation.

RISK OF ELECTRIC SHOCK

• 

Turn power off before inspection, installation, or removal.

Electrical Requirements

• 

Suitable for wet locations.

• 

Follow all National Electric Codes (NEC) and local codes.

Notes

These instructions cover both the standard EDGE Power/Data Translator (PDT) configuration and PDT 
configuration that includes the optional ColorWash controller.  The steps which differ between these two 
configurations are in separate sections, and it is only necessary to complete the ones that apply to the PDT 
being installed.

Customer Service

For technical assistance and installation support please call 800-285-6780 x2 or email [email protected]

Summary of Contents for EDGE

Page 1: ...azard if left unchecked This heating can also serve as an ignition source for gasses generated by the corrosion of metals inside of the enclosure Regularly scheduled inspections are recommended to ens...

Page 2: ...es Fixtures 2 Leader Cable s 3 Jumper Cable s 4 Termination Plug s 5 Mounting Brackets Ceiling or Wall 6 G G EDGE Power Data Translator PDT Includes controls power distribution and drivers 1 EDGE Stan...

Page 3: ...U fixtures in each string have 4 pin connectors THRU fixtures have a gray connector shell on the input end and a black connector shell on the output end while LEAD fixtures have black connector shells...

Page 4: ...ds using a chalk line or laser to mark the mounting bracket locations 2 4 and 6 fixtures require at least two mounting brackets Brackets should be installed near the ends of the fixtures 8 models requ...

Page 5: ...D at the bottom of the board below the driver fuses The input circuit shall be supplied with a 20A breaker on 120V systems or a 15A breaker on 277V systems Power Data Translator PDT Board The AC Input...

Page 6: ...The B outputs 1B and 2B have a limit of 40 feet G G recommends that the split be as even as possible within these limits For example if possible split 88 feet into a 48 foot string and a 40 foot stri...

Page 7: ...be connected to output 2A Failure to make the correct connections will lead to lighting effects being generated in an erratic manner To connect the leader cables to the LED Output terminals remove 2 3...

Page 8: ...ee discrete wires in the data cable these are marked on the board next to the terminals D D and COM Optionally the RJ45 8P8C connector can be used instead of the three terminals if the DMX source supp...

Page 9: ...be opened for outbound connections to allow the device to connect to our servers User Interface In order to access the ColorWash system you will need to create an account on the ColorWash dashboard a...

Reviews: