18. WARRANTY & SERVICE

18.1 Service

Cleaning Procedure

Prior to any cleaning of the controller, the mains power should be 
disconnected. Once powered off, use a 50% distilled water and 
50% isopropyl alcohol solution to clean the entire unit. A soft, non 
abrasive cloth will ensure no damage to the LCD screen and finish of 
the unit.

Service Requests

Service requests should go through customer center or local sales 
representative originally purchased through.
Upon notification, Gamma Vacuum or representative customer 
center will identify the level of service required. To assist in this 
process, please provide the following information in as much detail 
as possible:

• 

Part Number

• 

Serial Number

• 

Detailed Description of the Vacuum System Hardware

• 

Detailed Description of the Vacuum System Process (gas species 
introduced, ultimate pressure, operational pressure)

• 

Reason for Service Request

• 

Required Documentation

To expedite this process, please forward this information to  

[email protected]

.

Direct Support

Prior to recommending replacement parts or service at our facility, 
Gamma Vacuum can assist with general vacuum issues via e-mail 
or by telephone at no charge. It is our goal to have vacuum systems 
functional with minimal time and financial investment.
To do this, our service technicians require as much information as 
possible about the vacuum system in need of support. To assist in this 
process, please provide the following information in as much detail 
as possible:

• 

Part Number

• 

Serial Number

• 

Detailed Description of the Vacuum System Hardware

• 

Detailed Description of the Vacuum System Process (gas species 
introduced, ultimate pressure, operational pressure)

• 

Reason for Support Inquiry

To expedite this process, please forward this information to   

[email protected]

 or contact our facility directly at the 

numbers below.

18.2 Warranty

General Terms

Gamma Vacuum warrants to the Buyer that the equipment sold 
is new equipment, unless previously stated, and is, at the time of 
shipment to Buyer from Gamma Vacuum, free from defects in 
material and workmanship. As Buyer’s sole exclusive remedy under 
this warranty, Gamma Vacuum agrees to either repair or replace, at 
Gamma Vacuum’s option and free of parts charge to Buyer, and part 
or parts which, under proper and normal conditions of use, prove 
to be defective within twelve (12) months from the date of receipt by 
buyer.
As expendable items may have a life time of less than one year, their 
warranty is subject to reasonable service and will be replaced as 
determined by Gamma Vacuum. All warranty claims must be brought 
to the attention of Gamma Vacuum within thirty (30) days of failure 
to perform.
This warranty does not cover loss, damage, or defects resulting 
from transportation to the buyer’s facility, improper or inadequate 
maintenance by buyer, buyer supplied software or interfacing, 
unauthorized modifications of misuse, operation outside of 
environmental specifications for the equipment or improper site 
preparation and maintenance.
In-warranty repaired or replacement parts are warranteed only for 
the remaining unexpired portion of the original warranty period 
applicable to the parts which have been repaired or replaced. After 
expiration of the applicable warranty period, the Buyer shall be 
charged at Gamma Vacuum’s then current prices for parts, labor, 
and transportation.
Reasonable care must be used to avoid hazards. Gamma Vacuum 
expressly disclaims responsibility for any loss or damage caused 
by the use of its products other than in accordance with proper 
operating and safety procedures.
EXCEPT AS STATED HEREIN, GAMMA VACUUM MAKES NO 
WARRANTY, EXPRESSED OR IMPLIED (EITHER IN FACT OR BY 
OPERATION OF LAW), STATUTORY OR OTHERWISE: AND, 
EXCEPT AS STATED HEREIN, GAMMA VACUUM SHALL HAVE NO 
LIABILITY FOR SPECIAL OR CONSEQUENTIAL DAMAGES OF 
ANY KIND OR FROM ANY CAUSE ARISING OUT OF THE SALE, 
INSTALLATION, OR USE OF ANY OF ITS PRODUCTS.
Statements made by any person, including representatives of Gamma 
Vacuum, which are inconsistent or in conflict with the terms of this 
warranty shall not be binding upon Gamma Vacuum unless reduced 
to writing and approved by an officer of Gamma Vacuum.
Gamma Vacuum may at any time discharge its warranty as to any 
of its products by refunding the purchase price and taking back the 
products.

Summary of Contents for DIGITEL MPCq

Page 1: ...DIGITEL MPCq CONTROLLER USERS MANUAL Document 900034 Rev B ISO 9001 2015 Certified...

Page 2: ...able 7 Command CRC Checksum 19 Table 8 Response CRC Checksum 19 Table 9 Gamma Protocol Commands 20 Table 10 Command Packet Struct Over Ethernet Connection 24 FIGURES Figure 1 MPCq Front Panel 6 Figure...

Page 3: ...OCEDER AL SERVICIO DE REPARACI N MANTENIMIENTO O REVISION INTERNA ACHTUNG GEFAHR ELEKTRISCHER SCHL GE VERLETZUNGS ODER LEBENSGEFAHR TRENNEN SIE ALLE ELEKTRISCHEN ANSCHL SSE VON DER SPANNUNGSVERSORGUNG...

Page 4: ...nect the high voltage cable with the power on After turning the power off allow at least one minute before disconnecting electrical equipment 5 Do not operate the controller without a proper electrica...

Page 5: ...le 8 HV CONTROL ION PUMP OPERATION 8 1 Prior to using an ion pump Confirm following Rough pump down to 1x10 4 Torr or less the lower the better 1x10 6 Torr is recommended See Rough Pump user manual fo...

Page 6: ...11 4 Supply Setup on page 8 S Configured pump size in l s See 11 4 Supply Setup on page 8 10 FRONT PANEL Figure 1 MPCq Front Panel 10 1 Description Front panel containts Main power on off rocker type...

Page 7: ...tches home screen to TSP view Button is available only if Remote TSP Controller is connected to the MPCq Controller Menu Invokes main menu Exit Clears screen hides control buttons Turn On Off Turns HV...

Page 8: ...bration zeroing process 11 5 Display Setup Figure 8 Display Setup Screen Available setup Brigtness Level Configures screen brightness level 1 10 Screensaver Configures screen saver on off state Turnin...

Page 9: ...iply current log value in step 1 by 1 Step 3 Add the offset value 7 7 8 0 3 Volts The analog output pin will read 0 3V Logarithmic Pressure Example Pressure 1x10 9 Torr Offset 11 Output state Normal S...

Page 10: ...t digital output is asserted OFF Pressure When pressure value gets above this point digital output is deasserted HV Error Function Digital output is asserted when supply error is detected HV Output St...

Page 11: ...gister map is available on Gamma Vacuum website under download section 11 12 Profibus Setup Figure 15 Profibus Setup Screen For Profibus information reference Profibus user manual document 900033 avai...

Page 12: ...f TSP cannot continue because Pressure Window is set but supply is off TSP Armed Outside the pressure window TSP cannot continue because Pressure Window is set but pump pressure is outside the pressur...

Page 13: ...s between each sublimation cycle Advance Options Configure Invokes TSP advance options window TSP1 TSP2 Selects TSP for which above parameters are configured 11 17 TSP Pressure Window Setup Figure 20...

Page 14: ...ymore In comparison Active indicates error was detected and still active at this time Addition user intervention is required to clear the error Table 1 Error Status Codes 1 1 Error Status Code 1 2 Des...

Page 15: ...request 13 3 Connector J115 NET Profibus optional Standard Sub D 9 pin female connector Connection to Profibus interface For Profibus information reference Profibus user manual document 900033 availa...

Page 16: ...connected 28 Not connected 29 Reserved do not use ground 30 ANALOG OUT 1 output analog range 0 to 10VDC 31 Ground 32 ANALOG OUT 2 output analog range 0 to 10VDC 33 Ground 34 ANALOG OUT 3 output analo...

Page 17: ...e same serial port due to hardware loading limitations NOTE Must be supplied even when running RS 232 3 COMMAND CODE 2 ASCII hex characters Range 00 through FF See Table 9 Gamma Protocol Commands on p...

Page 18: ...ror Codes on page 18 NOTE If there is not an applicable error code a 00 will be transmitted 4 RESPONSE DATA As needed ACSII printable characters only Data field s are used to respond to commands reque...

Page 19: ...fy checksum for the response perform similar calculations Table 8 Response CRC Checksum 8 1 Characters 8 2 Value Decimal 8 3 Value Hex 0 48 0x30 1 49 0x31 space 32 0x20 O 79 0x4F K 75 0x4B space 32 0x...

Page 20: ...fied the current name is returned S TEXT TEXT Where S is supply 1 2 TEXT is string up to 15 characters FF SYS RESET Restarts the system N Where N is the reboot mode 0 Reboot 1 Reboot and start boot lo...

Page 21: ...Relay TTL output de energized Off Pressure must be at least 20 greater than On Pressure If not controller will automatically set Off Pressure to 20 greater than On Pressure 58 HV GET SET DIGITAL INPU...

Page 22: ...RE Reads upper TSP pressure See pressure window option R Z Ze ZZ Where R is TSP 1 2 Z Ze ZZ is the upper pressure 72 TSP GET ONTIME Reads TSP sublimation on time R D Where R is TSP 1 2 D is the on tim...

Page 23: ...e R is TSP 1 2 X is option Currently option 0 is only supported YY is a two digit status code 00 for TSP Initializing 01 for TSP Off 02 for TSP Armed Running 03 for TSP Armed Waiting pressure window s...

Page 24: ...if the first digit is a zero 4 DATA As needed ACSII printable characters only Data field s are for any commands that have a data value Not all commands require data field If command has more than one...

Page 25: ...er request SAFECONN Connector HV Interlock SMB with SHV 10 output connector or Mini Banana with Fisher output connector Display Controls 7 TFT WVGA 800x480 Color LCD 16 9 aspect ration Touchscreen Com...

Page 26: ...ma Vacuum free from defects in material and workmanship As Buyer s sole exclusive remedy under this warranty Gamma Vacuum agrees to either repair or replace at Gamma Vacuum s option and free of parts...

Page 27: ...on can be provided Original Purchase Order Number Gamma Vacuum Sales Order Number Product Order Number and or Product Description Product Serial Number All products received for repair or replacement...

Page 28: ...rimental to the operation of UHV products Hazardous substance means a chemical or substance or mixture of chemicals or substances which is regulated by the Federal Occupational Safety and Health Admin...

Reviews: