![background image](http://html1.mh-extra.com/html/gama/easy-spray/easy-spray_service-manual_3305448031.webp)
Service Manual
31/46
Issue 3.1
Ref. NR-00019-ENG
http://www.gamapur.com/
z) When the products come out without the contamination produced by the effect of the
DOTP cleaning agent, the cleaning process is complete and you can proceed as
normal.
aa) Close the
“RETRATC” valve (horizontal position).
bb) Turn the general switch
“OFF”. The temperature regulator displays will go out.
cc) Close the coupling block and mount the gun.
dd) Close the manual valves at the bottom of the tanks.
ee) Follow the Start up Procedures if change the chemical products.