![background image](http://html1.mh-extra.com/html/gama/easy-spray/easy-spray_service-manual_3305448010.webp)
Service Manual
10/46
Issue 3.1
Ref. NR-00019-ENG
http://www.gamapur.com/
1. Isocyanate Tank
Contains the A chemical element. Capacity 30 liters.
2. Polyol Tank
Contains the R chemical element. Capacity 30 liters.
3. Isocyanate Recirculation Valve
Allows selecting recirculation or spraying in the Isocyanate circuit.
4. Polyol Recirculation Valve
Allows selecting recirculation or spraying in the Polyol circuit.
5. Control Panel
Controls and regulates the correct operation of the unit.
6. Isocyanate Proportioning Pump
Meters the Isocyanate.
7. Polyol Proportioning Pump
Meters the Polyol.
8. Isocyanate Heater
Heats the Isocyanate to the pre-set temperature.
9. Polyol Heater
Heats the Polyol to the pre-set temperature.
10. Hose Heating Transformer (Optional)
Supplies the required voltage for heating the hoses.
11. Hose Electrical Regulator (Optional)
Set the electric power desired for heating the hoses.
12. Isocyanate Pressure Gage
Indicates the pressure in the Isocyanate circuit.
13. Polyol Pressure Manometer
Indicates the pressure in the Polyol circuit.
14. Isocyanate Heater Probe
Provides information on the temperature of the Isocyanate
15. Polyol Heater Probe
Provides information on the temperature of the Polyol.
16. Isocyanate Inlet Filter
Avoids the penetration of solid particles inside the Isocyanate pump of the unit.
17. Polyol Inlet Filter
Avoids the penetration of solid particles inside the Polyol pump of the unit.
18. Main Pneumatic Valve
It opens and closes the flow of air coming into the pneumatic system.
19. Retract Valve
Sets the piston rod of the Isocyanate proportioning pump to the retract position and prevents the
crystallization of Isocyanate on the piston rod. Close the RETRACT valve every time the unit is
stopped by the operator.
20. Pressure Regulators
Using the two air pressure regulators, select the pressure for the down stroke and the up stroke