Manual de Servicio
26/46
Issue 3.1
Ref. NR-00019-ENG
http://www.gamapur.com/
NOTE:
Assure the proper mechanical and electrical connection of the hoses to avoid
possible product leakage and hose heat problems.
e) Connect the air hoses.
f) Connect the hoses to the connectors of the coupling block of the gun, making sure that
the manual valves are closed.
g) Insert a contact thermometer through the hose insulation so that the bottom of the
thermometer is in contact with the hoses and the top is outside the insulation. Fit the
thermometer in such a way that the operators can see the temperature when they are
spraying. If the hoses have STC probes to automatically control the temperature, the
contact thermometer will not have to be installed.
h) Fill the Isocyanate and Polyol Tank