EN
ER31
The internal
configurations of the
TC* and induction are
incongruous
ER31 is
displayed
continuously
The internal
configuration data of
the induction
generator is different
from the configuration
inside the TC*
Download the configuration.
If the error is still present,
replace the TC*. If the error is
still present, replace the
induction generator.
ER35
Internal error at TC*
Shutdown
-
Replace TC*
ER36
Internal error at TC*
Shutdown
-
Replace TC*
ER42
Secondary power
supply not suitable
12V or 5V too high / too low
ER47
No communication to
at least one coupled
LIN
ER47 is
displayed
continuously
Damaged LIN cable. No
supply voltage for
coupled LIN.
Faulty coupled LIN.
Check and replace the LIN
wiring.
Check the supply voltage.
Replace coupled LIN.
(*) TC = Touch Control (Control Panel)
VI.2 ASSISTANCE SERVICE
Before contacting the Assistance Service it is important to:
-> Check if the problem can be resolved by consulting the error table in the
"Errors/Troubleshooting" paragraph.
-> Switch the appliance off and on again (ON/OFF) to make sure that the problem has been
resolved.
Finally, if after carrying out the above checks the error signals persist, contact the Assistance
Service.