21
EN
These appliances must be connected to an earthed system.
The appliance must be connected to the electrical mains system, interposing an omnipolar switch
which ensures disconnection from the network, with an opening distance of the contacts which
allows complete disconnection under the conditions of overvoltage category III, in compliance with
the installation rules (Fig.3.4.1).
The earth connection (yellow-green cable) must never be interrupted.
The power cable must be long enough to allow connection of the appliance, built into the appliance,
to the mains. If the power cable is damaged, it must be replaced in order to prevent any risk.
Protection against live parts must be ensured after installation.
Connection to the mains must be made using an earthed plug or an omnipolar circuit breaker
device with a contact opening of at least 3 mm.
The power cable must be positioned in such a way as not to touch the hot parts of the hob or
anything else.
To connect the appliance to the mains, use a power cable with a minimum conductor section of 2.5
mm2 for power up to 7360 Watt.
At no point should the cable reach a temperature 50°C higher than ambient temperature.
We cannot be held responsible for any accidents resulting from incorrect connection or which
may arise from using an appliance which has not been earthed or which has been fitted with
a faulty earth connection.
Fig. 3.4.1