d Cod. 80000230a – 01.12.2014
Min. Temperature recorded
-
Press and release the
DOWN
button.
-
The “Lo” message will be displayed followed by the minimum temperature recorded.
-
By pressing the
DOWN
button again or by waiting 5sec. the normal display will be restored.
Max. Temperature recorded
-
Press and release the
UP
key.
-
The
“Hi”
message will be displayed followed by the maximum temperature recorded.
-
By pressing the
UP
key again or by waiting 5s the normal display will be restored.
Reset of the Min. and Max. Temperature recorded
-
Hold press the
SET
button for more than 3s, while the max. or min temperature is displayed. (
“rSt”
-
message will be displayed).
-
To confirm the operation the “rSt” message starts blinking and the normal temperature will be
displayed.
Defrostings
The controller is programmed in factory to perform a given number of defrost cycles during the 24 hours.
Duration of defrost cycles can vary, and it depends on the temperature detected by a specific sensor placed
inside the evaporator (defrost sensor). Such sensor determines the end of the defrost, unless a maximum
(settable) safety duration is reached.
Manual defrostings
Push the
DEF
button for more than 2 seconds and a manual defrost will start. The defrost cycle will take
place according the criteria mentioned above (once reached the defrost temperature- detected by the
defrost sensor, or in case the defrost exceed the safety duration).
Alarm warnings
When an alarm is activated, the display shows the corresponding message. The alarm codes are shown in
the table below:
Summary of Contents for GIANO 70
Page 16: ...11 Cod 80000080c 17 07 2018...
Page 24: ...19 Cod 80001850 10 11 2014 X8 X8 X4 X4 X2 X2 4 5 6 7 8 9 10 11...
Page 25: ...20 Cod 80001850 10 11 2014 X8 X4 12 13 14...
Page 28: ...23 Cod 80002380a 04 08 2015 15 16 17 X2 18 X2 20 21 22 10 18 19...
Page 29: ...24 Cod 80002380a 04 08 2015 23 24 X2 26 X2 27 X2 28 24 27 25...
Page 45: ......
Page 46: ......
Page 47: ......