26
The Attack Time [A] can be edited using the “NAV/PM1” encoder, the Release Time [R] the “PM2” encoder
and the Limiter Active Threshold the “PM3” encoder.
“
Attack Time [A]
”: the selectable range of the Limiter's Attack Time is from 5ms to 200ms in steps of 1ms -
from 5ms to 20ms, then 5ms - from 20ms to 30ms, then 10ms - from 30ms to 100ms, and 20ms - from
100ms to 200ms.
The Limiter's Attack Time can be adjusted by rotating the “NAV/PM1” encoder.
“
Release Time [R]
”: the selectable range of the Limiter's Release Time is from 0.1s to 3s in steps of 0.1s
and can be adjusted by rotating the “PM2” encoder.
“
Limiter Active Threshold
”: the selectable range of the Limiter's Threshold is from +20dB (Limiter not
active) to -10.0dB in steps of 0.2 dB and can be adjusted by rotating the “PM3” encoder.
Note1
: Once the desired options have been selected using the 3 encoders, they are automatically saved as
current and stored in the DS-SP36 system status once leaving the page.
Note2
: To exit this page, push the “ESC” button.
Delay page –
from this page it is possible to set the Output Channels Delay Time from 000.0000mS up to
848.9984mS, by steps of 1mS or 20.8uS.
To set the Delay time, press ENTER, and an arrow will appear on the left of the screen “ -> ”. Then use the
“PM2” encoder to set the Delay Time in steps of 1mS and the “PM3”, for setting the “fine” Delay Time in
steps of 20.8 microseconds.
The following is an example screen for the “Delay” page where the Delay Time of Output Channel 1 is set
to 160.1872mS:
Polarity page –
from this page it is possible to set the Output Channels Polarity, by using the “PM1” or
“PM2” encoders.
The polarity can be “Normal” or “Inverted” (which means rotated of 180 Degrees).
The following is an example of a “Polarity” screen where the Polarity of Output Channel 1 is set to “Normal”
Out-1 Name Delay
–› Delay 160.1872mS
Out-1 Name Polarity
–› Polarity = Normal