47
GROUP 5: DIGITAL I/O PARAMETERS
Par.
No
Description
Range
Unit
Default Setting
Display
Related Par.
202
Infrared
Output Type
0 – 2
0: Disable
1: NPN (active LOW) (
DF)
2: PNP (active HIGH)
Infrared Type
203
DCL Reset
0 - 1
0: Enable door position
reset in DCL. (
Default)
1: Disable door position
reset in DCL.
DCL Reset
204
DOL
for
Narrower Door
0 – 1
0: Use regular as DOL of
Narrower Door DOL (
DF)
1: Use AUX as DOL of
Narrower Door DOL
DOL for Nar Door
205
Buzzer Disable
0 – 1
0: Buzzer Disable (
DF)
1: Buzzer Enable (Continue)
2: Buzzer Enable (ON – OFF)
Buzzer Disable
206
Holding Time
for
Edges Timeout
relay
0.0 –
180.0
sec
3sec (
Default)
EdgesTimeout HLD
207
Reopen Relay
Mode
1 - 0
0: MAINTAIN
1: DISABLE WHEN EDGES
RELAY ON
Reopen Relay MOD
219
Nudging Torque 0 - 400
A
173
Nudging Torque
GROUP 6: PROTECTION PARAMETERS
Par.
No
Description
Range
Unit
Default Setting
Display
Related Par.
216
DC Brake Duty
0 - 100
%
50%
Dynamic Brake
217
Motor
Overload Current
0.0 – 6.0
A
2.5A
Motor Overload
221
Number
of Retries
after Faults
0 -10
6
No of Retries
222
Retry
Waiting Time
0.2 –
120.0
sec
2.5sec
Restart time
226
Auto Reset Time
Reset after Fault
9999 - 0
Sec
600
Restart rst T
228
Motor
Overload
Selection
0 - 2
00: Standard Motor
01: Special Motor (
DF)
02: Disabled
Motor OL Sel
229
Motor
Overload Time
30 - 600
sec
60sec
Motor OL Time
47
Summary of Contents for MOVFE 2500
Page 1: ...2500 3069 1 888 425 2262 2500 3069 ELECTRICAL...
Page 2: ...Rev 1 10 20 I...
Page 24: ...19 6 DEFAULT PARAMETERS 19...
Page 26: ...21 FAULTS AN EXAMPLE OF FAULTS DISPLAY COUNTERS 21...
Page 27: ...22 USER LIST 22...
Page 28: ...23 23...
Page 29: ...24 24...
Page 30: ...25 25...
Page 31: ...26 MAXIMUM CLOSE SPEED AND FORCE 26...
Page 32: ...27 ECI DEFAULT PARAMETER SETS 27...
Page 34: ...29 SPEED PROFILES OF THE VFE2500 FOR NORMAL DOOR 29...
Page 35: ...30 SPEED PROFILES OF THE MOVFE2500 FOR HEAVY DOOR 30...
Page 36: ...31 SPEED PROFILES OF THE MOVFE2500 FOR NARROW DOOR 31...
Page 91: ...Rev 10 20 85...
Page 92: ......