44
GROUP4:CLOSEDIRECTIONPARAMETERS(CONTINUED)
Par.
No
Description
Range
Unit
DefaultSetting
Display
RelatedPar.
161
Heavy
Close
DecelerationTime
0.1–
3600.0
sec
6sec:HarmonicC/P
8sec:HarmonicS/O
12sec:LinearStraightC/P
18sec:LinearStraightS/O
8sec:LinearGearedC/P
2sec:LinearGearedS/O
HvyClo.Dec.
163
Heavy
StallReverse
Force
0.0–4.5
A
1.8A:HarmonicC/P
2.2A:HarmonicS/O
1.6A:LinearStraightC/P
1.6A:LinearStraightS/O
0.8A:LinearGearedC/P
1.1A:LinearGearedS/O
HvyStallNormal
165
Heavy
CloseMid.Volt
0.0–
100.0
%
4%
HvyCloseMid.V
166
Heavy
Close
Mid.Frequency
0.00–
400.00
Hz
0.5Hz
HvyCloseMid.F
167
Narrow
Close
HoldingTorque
0.0Ͳ4.5
A
0.6A:HarmonicC/P
0.6A:HarmonicS/O
0.6A:LinearStraightC/P
0.6A:LinearStraightS/O
0.2A:LinearGearedC/P
0.2A:LinearGearedS/O
NarCloHLDTorq
168
Narrow
Close
HoldingSpeed
0.00–
400.00
Hz
2Hz
NarCloseHLD
169
Narrow
Close
HoldingStart
0.0–
100
%
3.0%:HarmonicC/P
3.0%:HarmonicS/O
2.0%:LinearStraightC/P
2.0%:LinearStraightS/O
2.0%:LinearGearedC/P
2.0%:LinearGearedS/O
NarHLDStart
170
Narrow
CloseTorque
0.00–
400.00
Hz
243Hz:HarmonicC/P
173Hz:HarmonicS/O
270Hz:LinearStraightC/P
270Hz:LinearStraightS/O
100Hz:LinearGearedC/P
120Hz:LinearGearedS/O
NarCloseTorq.
44
Summary of Contents for MOVFE 2500
Page 1: ...2500 3069 1 888 425 2262 2500 3069 ELECTRICAL...
Page 2: ...Rev 1 10 20 I...
Page 24: ...19 6 DEFAULT PARAMETERS 19...
Page 26: ...21 FAULTS AN EXAMPLE OF FAULTS DISPLAY COUNTERS 21...
Page 27: ...22 USER LIST 22...
Page 28: ...23 23...
Page 29: ...24 24...
Page 30: ...25 25...
Page 31: ...26 MAXIMUM CLOSE SPEED AND FORCE 26...
Page 32: ...27 ECI DEFAULT PARAMETER SETS 27...
Page 34: ...29 SPEED PROFILES OF THE VFE2500 FOR NORMAL DOOR 29...
Page 35: ...30 SPEED PROFILES OF THE MOVFE2500 FOR HEAVY DOOR 30...
Page 36: ...31 SPEED PROFILES OF THE MOVFE2500 FOR NARROW DOOR 31...
Page 91: ...Rev 10 20 85...
Page 92: ......