Action
Clean handset spray plate - see cleaning and
maintenance section
Check with installer or local water authority
(See Important Information - Pressures section)
Check inlet requirements (see Important Information -
Pressures section), and ensure no other main water
devices are being used whilst showering
Increase the flow by turning the temperature control
knob in an anticlockwise direction. Check and clean the
handset.
Increase the flow by turning the temperature control
knob in an anticlockwise direction. Shower has sensed
high outlet temperature and is increasing the available
flow to reduce temperature until the temperature dial is
adjusted correctly.
Clean the handset - see cleaning and maintenance
section
Adjust the spray plate to improve the pattern
Flow rate will naturally be lower when the inlet
temperature is low, this applies to all electric showers.
Consult electrician
Symptom
Water too hot
Temperature
varies
dramatically
while showering.
Poor spray
pattern.
(refer also to
handset
instructions)
Possible cause
Spray plate blocked wth
scale or debris
Water pressure too low.
At times of high inlet
temperature a cold
shower may not be
obtainable.
Water pressure too low
or unstable
Thermal cut-out is
operating, normally
making a “click” as it
does so.
Over temperature
device, (except model
201-01703) see rating
label.
Partially blocked
handset
Multi pattern handset
incorrectly set.
Low water inlet
temperature.
Low voltage
! These checks must only be performed by a competent person
16
Isolate electricity for shower at fuse box, remove cover
and check switches come on (click) when water begins to
flow. If not then check pipe work for potential blockages/
pressure losses. See Important Information - Pressures
section page 4 and commissioning page 12.
Trouble shooting guide
Page 3 of 4