25
APPENDIX
A-1. Function & Relay configuration by software
1). “1Y/1X/2Y/2X” Function Setting:
Item
Title
Content
Description
1 (1Y)/(1X)/(2Y)/(2X)
Relay Counter
1. (1Y)/(1X)/(2Y)/(2
X) N/A
2. (1Y)/(1X)/(2Y)/(2
X)
Choose
1
Relay
to
16
Relays
(1Y)/(1X)/(2Y)/(2X) N/A:
Each axis of “Joystick #1”and “Joystick #2”
can reach 0. Relay configuration can be
arbitrarily set by software at any speed.
(1Y)/(1X)/(2Y)/(2X) Choose 1 Relay to 16
relays:
Each axis of “Joystick #1”and “Joystick #2”
can reach 1 to 16 Relay(s) configuration
can be arbitrarily set by software at any
speed.
2 (1Ynorth))/(1XWest)/
(2YUp)/(2XauxDown)
Acce. Delay
Acce.Delay
0 Sec.to 4 sec.
Select
the
time
interval
for
each
acceleration.
3 (1YSouth))/(1XEast)/
(2YDown)/(2XAuxUp)
Acce.Delay
Acce.Delay
0 Sec.to 4 sec.
Select
the
time
interval
for
each
acceleration.
4 (1YNorth))/(1Xeast))/
(2YUp)/(2XupxDown)
Inching
Inching
0.05 Sec..to 0.8 Sec.
Select the time interval of each inching
motion.
5 (1YSouth))/(1Xeast))/
(2YDown)/(2xAuxUp)
Inching
Inching
0.05 Sec.to 0.8 Sec.
Select the time interval of each inching
motion.
6 (1Y)/1X)/(2Y)/(2X)
Interlock Delay
Interlock Delay
0 Sec. to 4.0 Sec.
Interlock:
If it is dangerous or improper to
operate two motions at the same time,
select “Interlock”. Delay time means the
time interval before next motion is valid.
2). “SW1, SW2” Rotary switch Function Setting:
Item
Title
Content
Description
1 Switch1 Function 1. Enable SW1A/SW1B
2. Disable SW1A/SW1B
Disable
: Disable SW1A/SW1B function.
Enable:
Enable SW1A/SW1B function.
2 Switch2 Function 1.Enable SW2A/SW2B
2.Disable SW2A/SW2B
Disable
: Disable SW2A/SW2B function.
Enable:
Enable SW2A/SW2B function.