18
3-3
Wiring
TECHNICAL INFORMA
TECHNICAL INFORMA
TECHNICAL INFORMA
TECHNICAL INFORMA
TECHNICAL INFORMATION 3
TION 3
TION 3
TION 3
TION 3
3-3.1 Immersion Heater - 500 Cylinders
Fig. 3-3a Immersion Heater Wiring Diagram - 500 Cylinder
500 cylinders have three 2kW immersion heater elements (total 6kW) and must
be wired using 3 x 2.5mm² 20amp 3-core Heat Resistant Cables as shown.
B1
A1
B2
A2
B3
A3
1
3
4
6
2
5
THERMOSTAT
With Thermal Safety
Device
HEATING
ELEMENTS
BOTH PHIALS ARE
INSERTED IN THIS HOLE
L1
L2
L3
N1
N2
N3
EARTH
TERMINAL
3 x 2.5mm² 20A 3-CORE
HEAT RESISTANT CABLE
L1
L2
L3
green/ yellow
blue
brown
L1
L2
L3
6
4
2
5
3
1
N
L
3 x 2kW
HEATING
ELEMENTS
3 x 2.5mm² 20A 3-CORE
HEAT RESISTANT CABLE
45 AMP
DOUBLE POLE SWITCH
THERMOSTAT
With Thermal Safety Device
blue
blue
brown
brown
6mm² 32A 3-CORE
3 x LIVE WIRES
supplied
AMP TAG CONNECTIONS
IMPORTANT
ENSURE ALL TERMINALS
ARE TIGHT AND CORRECT
33333