![GAF DecoTech Installation Instructions Manual Download Page 37](http://html.mh-extra.com/html/gaf/decotech/decotech_installation-instructions-manual_555829037.webp)
P a g e
|
37
Stretch a mason line along the top edge of the row of Solar Module Assemblies to verify that
all of the Assemblies are at the same height (
Figure 37
). Adjust the feet as necessary.
Figure 37 Checking Height of Solar Module Assemblies
The height of the foot can be adjusted from a minimum 1.72 inches to a maximum 3.15 inches.
(
Figure 38
). If height adjustments are needed:
1.
Loosen the carriage bolt and nut.
2.
Align the interface to the correct tooth groove height
3.
Retighten the carriage bolt and nut to 125 inch-pounds (14.12 Nm). The nut may be
re-torqued up to 3 times when adjusting the height.
Step 4b
:
Make Electrical Connections between MLPEs…
Complete the wiring according to the Permit
Design Drawings. Typical connections are shown in
Figure 39
. Follow proper wire
management techniques to secure the wires.
Mason Line
along the Top
Edge of Solar
Module
Assemblies
1.72"
3.15"
Figure 38 Foot Adjustment Range