P a g e
|
27
For slopes between 4:12 and 6:12, side and end laps should be fastened 12 inches (305 mm)
on center (o.c.) and 24 inches (610 mm) o.c. elsewhere. Stagger each row of 12 inches spaced
fasteners. The side lap should be overlapped 3 inches (76 mm) and end lap 6 inches (152
mm).
For slopes greater than 6:12, side and end laps should be fastened 9 inches (228 mm) o.c. and
18 inches (457 mm) o.c. elsewhere. Stagger each row of 9 inches spaced fasteners.
Figure 20 Install VersaShield SOLO Fire-Resistant Slip Sheet
Note
To avoid interference with the Starter Bar, do not install the first row of cap nails along the lower
edge of the VersaShield® SOLO™ Fire-Resistant Slip Sheet.
VersaShield
®
SOLO™
Fire-Resistant
Slip Sheet
Leak Barrier
1
2
3
1.5"
VersaShield
®
SOLO™ Fire-
Resistant Slip
Sheet
QuickStart
®
Peel and Stick
Starter Roll
Leak Barrier