2. WIRING
2-7
How to connect the Accu-Steer FPS 12V/24V helm sensor
2.2.6
Teleflex linear sensor
To connect a Teleflex linear sensor AR4502 (instead of the FAP-6112), do the following
modification.
1. Make the cable connection as shown below. Refer to the installation manual of the lin-
ear sensor for recommended cable.
2. Set the RRU type to [LINEAR SENSOR] on the [DOCKSIDE SETUP] menu when you
do the initial settings, in the next chapter.
MOTOR A+ MOTOR B-
GND
POWER + POWER -
SOL A
SOL B
TB1
TB2
Accu-Steer FPS
12V/24V
Brown
Black
Blue
Brown
Black
Blue
TB5
1
2
3
4
5
SPU Board
(64P1158)
TB10
LINEAR SENSOR
AR4502
RED
WHT
BLK
PROCESSOR
UNIT
Wind tape where shield was removed.