1. OPERATIONAL OVERVIEW
1-7
1.4.2
Raising the transducer
Press the
key to raise the transducer. The lamp above the switch flashes and the
message "RAISING " appears. while the transducer is being raised. When the trans-
ducer is above the sea surface the, transmission is stopped the message "TX
STOPPED" appears for three seconds. When the transducer is completely retracted,
the message "RETRACTED" appears and the lamp above the
key lights steadily.
Note:
If the transducer is not raised within approx. 20 seconds (1200 stroke) or 25
seconds (1600 mm stroke) the message "TRANSDUCER NOT RETRACTED" ap-
pears. If this occurs, see section 8.12.2 for how to retract the transducer manually.
1.4.3
How to check how far the transducer is projecting
The Transducer Position Mark, which appears at the top left corner, lets you check
how far the transducer is projecting. You can show or hide the marker by doing the
following operation: [Menu]
→
[Initial Settings]
→
(Change confirmation window)
→
[Mark
Display]
→
[TD Position Mark].
Notes
The color of the indicator changes according to transducer position and operation
state.
• Green: The transducer is fully retracted.
• Brown-yellow: Transducer stopped at position other than “retracted”.
• Red: The transducer is being raised or lowered.
If the transducer position cannot be detected the transducer mark flashes. Further, the
bar is not displayed, and the amount of projection is indicated as “**%”.
How to set mid position
With [Mid Key Setting] in the [Others] menu set to [Fixed Position],
click the transducer position mark to show the window shown in the
right figure. Click
S
or
T
to change the setting. Click Quit to close
the window.
0%
100%
TX start point:
TX starts when the transducer is projecting
below this mark.
Mid protrusion mark:
Position where transducer stops after mid
protrusion key is operated.
(Mid protrusion key programmed for [Fixed
Position.]
Current projection distance indicated by
percentage.
Completely retracted: 0%
Completely extended: 100%
Quit
Cancel
5%
(5~95)
Mid protrusion
Summary of Contents for FSV25S
Page 1: ...COLOR SCANNING SONAR FSV 25 FSV 25S OPERATOR S MANUAL www furuno com Model ...
Page 14: ...SYSTEM CONFIGURATION xii This page is intentionally left blank ...
Page 32: ...1 OPERATIONAL OVERVIEW 1 18 This page is intentionally left blank ...
Page 92: ...4 NUMERIC GRAPHIC DATA DISPLAY 4 4 This page is intentionally left blank ...
Page 126: ...7 RECORD RECALL OPERATION 7 10 This page is intentionally left blank ...
Page 156: ...APPENDIX 1 MENU TREE AP 6 This page is intentionally left blank ...
Page 160: ...FURUNO FSV 25 25S SP 4 E1344S01C 140402 This page is intentionally left blank ...
Page 163: ......