ATR833 / P/N 833-(1xx)-(1xx)
Operation and Installation
Quick approach:
•
Select or enter a Standby-Frequency, which should be additionally
monitored.
•
Set SQ with the
key and the
rotary knob to a value of at
least 02.
•
Activate DUAL Watch with
(DUAL is shown)
•
As soon as no reception is determined on the activate frequency,
the mutual monitoring between active and Standby-Frequency
starts (2 seconds Standby and 0.3 seconds active frequency)
•
In order to deactivate DUAL Watch: press
once more or change
the frequency.
2.6 Transmission
By pushing the PTT button, the device starts transmission on the
selected frequency (shown in the upper line).
“TX“ indicates correct operation of the transmitter.
In order to avoid unintended transmissions, the transmitter stops after
two minutes and the display changes from „TX“ to „Te“. In order to re-
start transmission, release PTT and push it again.
2.7 Reception
While receiving (squelch is open) “RX” is shown.
19