ATR833 / P/N 833-(1xx)-(1xx)
Operation and Installation
2.8 Enhanced Settings
In the following section configurations beyond the basic settings are
explained.
In order to save energy and to extent lifetime of the OLED Display an
automatic Darkening of the Display
“ENERGY SAVING MODE“ can
be configured.
The
Master Reset - Function
sets the user settings back to the factory
settings.
In the
SET UP - Menu
the frequency databases (including the user-
defined frequency list) can be deleted and the channel spacing can be
configured.
In the
MIC - Settings
the microphone sensitivity is configurable.
+ Turning on
Energy Saving Mode
+
+Turning on
Master Reset (Factory Settings)
+ Turning on
SET-UP Menu
Press
longer than 5 seconds MIC - Settings
2.8.1 Energy Saving Mode – Darkening the Display
Available since P/N 833-(103)-(101) software version V5.5
The Energy Saving Mode - Menu can be accessed by pressing the
key and the
key simultaneously.
With the
rotary knob a time span can be defined, after which the
display automatically darkens if no key or rotary knob was in use. The
time span can be set up to 30 minutes. The automatic darkening can be
deactivated with selecting the “Never“ option (default). By pressing the
key again, the setting is saved and the menu is left.
2.8.2 Master Reset - Set back to factory settings
Available since P/N 833-(103)-(101) software version V5.5
The factory settings can be reset only from the switched-off device. In
order to reset to factory settings press the
key (to switch on), the
key and the
key simultaneously. The display shows
“SETTING RESTORE“. After releasing the keys the settings are reset to
the factory settings. This will be confirmed by the message,
“SUCCESSFULLY“.
20