EP18-72-IOMM-2015-7
Fulton Ltd
Page 43
APPENDIX - A
Specification
TI-115-EP18-72-DS-2017-9
Page 2 of 2
Every effort is made to ensure accuracy at time of going to press. However as part of our policy of continual product improvement, we reserve the right to alter specifications without prior notice.
Telephone:
+44 (0) 117 972 3322
Fax:
+44 (0) 117 972 3358
E-mail:
Website:
www.fulton.co.uk
Fulton Ltd
5 Fernhurst Road, Fishponds, Bristol.
BS5 7FG. England.
FM 28400
003
FM 28400
MODEL: ELECTROPACK
UNIT
EP18
EP24
EP36
EP48
EP54
EP72
Designed and manufactured to BS EN 13445:2009 and PED 2014/68/EU.
General
Steam Output F & A 100°C
kg/h
29
38
57
77
86
115
kW Rating
kW
18
24
36
48
54
72
Operating Pressure
barg
10.34
10.34
10.34
10.34
10.34
10.34
Number of Elements
1
1
2
2
3
3
Weight
Shipping Weight
kg
390
390
390
390
390
390
Operational Weight
kg
560
560
560
560
560
560
Boiler working water volume
L
38
38
61
61
84
84
Feed Tank Volume
L
77
77
77
77
77
77
Electrical Requirements
FLC 400 V 3 ph 50 Hz**
A/ph
32
40
58
75
84
110
FLC 230 V 1 ph 50 Hz***
A
86
112
164
216
242
320
Connection Sizes
All threads BSP
F= Female, M=Male
Steam Outlet
DN
20
20
20
20
20
20
Safety Valve Discharge
DN
25
25
25
25
25
25
Condensate Return
DN
15
15
15
15
15
15
Feedwater Inlet
DN
20
20
20
20
20
20
Feedwater Pump Inlet
DN
25
25
25
25
25
25
Blowdown, Boiler
DN
20
20
20
20
20
20
Blowdown, Water Level Gauge
(Sight Glass) - where fitted
DN
15
15
15
15
15
15
Feedwater Tank Vent
DN
40
40
40
40
40
40
Feedwater Tank Drain
DN
15
15
15
15
15
15
Feedwater Tank Overflow
DN
25
25
25
25
25
25
Water Sample Outlet
DN
15
15
15
15
15
15
** 6 A/ph for feedwater pump & standard control circuit, included.
*** 7.5 A for feedwater pump & standard control circuit, included.
Note:
Electrical enclosures are rated IP20