21
The 12V battery charging outlet
(21) is suitable for charging most lead acid type car
batteries.
Before charging, remove the battery from the vehicle. The battery MUST be totally isolated
from any other circuitry.
1. Connect the positive (+, RED) charging cord to the positive
battery terminal. Connect the negative (-, BLACK) charging
cord to the negative battery terminal (Fig. 25). Do not
reverse the charging cables, or serious damage to the
generator and/or the battery may occur.
2. Start the generator and allow it to warm up (see
Starting
the generator
)
3. Connect the DC cable (27) to battery charging socket (21)
(Fig. 26). The battery will begin charging.
4. When disconnecting, remove the plug from the generator
before unclipping the clamps on the battery.
Note:
Do not attempt to charge lithium ion, NiCad or NiMH batteries. The charging outlet is
only intended for Lead Acid batteries.
The USB outlet
(15)
outputs power with a rating of 1A at 5V.
It is suitable for charging mobile phones, MP3 players etc.
Before plugging the appliance into the USB port, check that
its rating does not exceed 1A or 5W. Allow the generator to
warm up before connecting the appliance to the USB outlet.
OPERATION (cont.)
240V AC
12V DC 8.3A
REMOTE
CONTROL
STOP
OVERLOAD
RESET
ECON
ON OFF
ON
ON
START
STOP
OFF
ON
OFF
5V DC USB
5V DC USB
ECONOMY
ON
ON
OFF
OFF
REMOTE CONTROL
STOP
12V DC 8.3A
240V
STOP
START
ON
12V DC 8.3A
DC OVERLOAD
RESET
Fig. 25
Fig. 26
WARNING!
The battery gives off explosive gases; keep sparks, flames and
cigarettes away. Provide adequate ventilation when charging.
WARNING!
The battery contains sulphuric acid (electrolyte). Contact with skin or
eyes may cause severe burns. Wear protective equipment.
WARNING!
Always supervise battery charging - generator will not cut voltage to
battery and can overcharge. Disconnect when battery reaches 14V (Check with
multi-meter).
240V AC
12V DC 8.3A
REMOTE
CONTROL
STOP
OVERLOAD
RESET
ECON
ON OFF
ON
ON
START
STOP
OFF
ON
OFF
5V DC USB
240V AC
12V DC 8.3A
REMOTE
CONTROL
STOP
OVERLOAD
RESET
ECON
ON OFF
ON
START
STOP
ON
OFF
5V DC USB
DC OVERLOAD
RESET
Fig. 27
WARNING!
Batteries left unattended can potentially explode, resulting in serious
injury.
Summary of Contents for FBT-3300