17
Note: Pressing and holding the emergency stop button (24) will stop the generator from all
starting modes.
OPERATION (cont.)
Running-in the engine
It is advised that the operator should comply with the following instructions for the first
15 hours of usage:
1. After start-up, the generator should be allowed to warm up at low speed and with no
load for five minutes.
2. The generator cannot be run at high power in the running in stage. We recommend
running at 50% of rated load during this period.
3. Change the oil after the first 20 hours of operation.
Economy Switch
When the Economy Switch (16) is turned ON (I), the engine
will automatically enter idle mode after an electrical appliance
has been disconnected. It will return to the proper speed
required when the electrical appliance is connected. Having the
Economy switch ON is recommended, as it minimizes the fuel
consumption while in operation.
IMPORTANT: In DC operation, turn the Economy switch to the OFF (O) position.
WARNING!
When an extension cable is required, be sure to use a rubber sheathed
flexible cable. Limit length of extension cables: 60m for cables of 1.5mm
2
and 100m
for cables of 2.5mm
2
.
WARNING!
Keep the generator a distance at least 1 metre from other equipment
during operation.
CAUTION!
When high electrical loads are connected simultaneously, turn the
Economy switch (16) to the OFF position to reduce voltage fluctuation.
5V DC USB
ECONOMY
ON
ON
OFF
OFF
REMOTE CONTROL
STOP
12V DC 8.3A
240V
STOP
START
ON
12V DC 8.3A
DC OVERLOAD
RESET
Fig. 18