7
1.4.CONNECTION TO THE GAS SUPPLY: CURRENT INSTALLATION STANDARDS
The gas inlet connection is 1/2'BSP and is located 40mm from the left hand side of the cooker,
approximately 450mm from the base of the cooker (add the height of the adjustable leg to determine
the height from the floor). For Natural Gas installations, fit the Natural Regulator supplied with the
cooker. For Universal LPG, fit the test point assembly supplied with the cooker.
Riqid Pipe A rigid pipe connection may be used with this appliance provided it complies with AS5601
table 3.1.
Flexible Hose This appliance is suitable for connection with a flexible hose which complies with
AS/ANZ1869, 10 mm internal diameter, class B or D and between 1 to 1.2m long in accordance with
AS5601 high level connection. The hose should not be subjected to abrasion, kinking or permanent
deformation. The restraining chain supplied fitted to the rear of the cooker is moved forward from the
installed position. Unions compatible with the hose fittings must be securely fixed to the wall (lower
hook position) to prevent strain on the gas hose connections when the cooker.
The cooker is factory set for Natural gas. The test point pressure should be adjusted to 1.00 kPa with
one rapid burner operating at maximum. If installing for use with Universal LPG, a gas regulator
suitable for a supply pressure of 2.75kPa should be part of the gas tank supply.
After connection, check that there are no gas leaks by using a specific instrument or, more simply, using
soapy water.
1.5. CONNECTION TO THE ELECTRICITY SUPPLY
The cooker must be connected to the electricity supply using the cable supplied with the cooker,
approved under CEI 20/19 (HD 22.1.2.3.4 52-22.7.8 1) standards; we recommend using a plug as per
CEI 23-5,23-5/V2 standards. The amperage printed on the plug must always be above the maximum
amperage of the appliance. If the absorbed current is above 16A, the connection must be permanent
to the main supply, fitting a multiple polar switch between the cooker and the supply, with contact
openings of at lease 3 mm. (excluding the earth wire). The yellow-green supply cable (fig.5) must be
connected to an efficient earth System and the plug or multiple polar switch must be easy to inspect
once the cooker is installed.
IMPORTANT: Adaptors must not be fitted between the electric socket and the supply cable
to the cooker, Fig.6.
1.6. STABILIZING THE COOKER FREESTANDING
There are 2 lengths of chain fitted to both sides of the cooker at the rear.
Both of these chains should be securely fixed to the wall (upper hook
position) to prevent the cooker from tipping forward if a weight is placed
on the oven door. After fixing the chains to the wall, check that the
cooker cannot tip forward.
Summary of Contents for OVFS9-10
Page 35: ...NOTES ...