- 4 -
Control and test
►
Control of Electric Backups
H 33
EX 1
EX 2
EX 3
Outdoor
Unit Fault
Load-shedding (EJP)
O
ff
-peak/peak hours
External fault
(369)
(370)
0 V
230 V
230 V
0 V
230 V
0 V
230 V
EJP lock signal
(l 2920)
"Released"
"Locked"
ON
"Locked"
HEAT PUMP
OFF
ON
ON
OFF
ON
ON
ON
OFF
DHW auxiliary
ON (1)
ON
OFF
OFF
ON
OFF
ON
OFF
1st stage elec.
auxiliary
ON (2)
ON
OFF
OFF
ON
ON
ON
OFF
2nd stage elec.
auxiliary
ON (2)
ON
OFF
OFF
ON
ON
ON
OFF
Boiler backup
ON (2)
ON
ON
ON
ON
ON
ON
OFF
(1) subject to authorization by EX2.
(2) provided the outdoor temperature is less than the setting on "2884 or 3700" (+2° from the beginning).
►
Sensor and Input Test Mode
LINE
SENSOR INPUT
OUTPUT
WATERSTAGE
7700
QX
Relay test
7710
UX1
Output test
7712
UX1
PWM-Signal
7722
DO2
Cooling mode
7723
D3
Heat pump
7724
UX3
Output test ("Inverter" command)
7725
UX3
Voltage signal (Ux3)
7820
BX1
Sensor temp (HP fl ow temperature)
7821
BX2
Sensor temp (HP return temperature)
7822
BX3
Sensor temp (DHW temperature)
7823
BX4
Sensor temp (Outside temperature)
7911
EX1
Input (Power shedding, EJP)
7912
EX2
Input (Tariff s day/night)
7913
EX3
Input (External fault)
7973
BX31
Sensor temp (Mixing circuit temp.)
7976
BX34
Sensor temp (Swimming pool exchanger temperature)
7996
H33
Contact state
Waterstage / Maintenance Manual / 2105 - EN