1-15. COMPRESSOR PREHEATING
When the outdoor temperature is lower than 0°C and the all operation mode has been
stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started and when the outdoor temperature rises to 25°C or greater,
preheating is ended.
1-16.
10
°
C HEAT OPERATION
The 10°C HEAT
operation
The 10°C HEAT
The 10°C HEAT
operation can be set by the wireless remote controller.
functions by pressing 10°C.HEAT button on the remote controller.
operation is almost the same operation as below settings.
Mode Heating
Setting temperature 10°C
Fan mode AUTO
( Table9 )
1-17.
ECONOMY OPERATION
The ECONOMY operation functions by pressing ECONOMY button on the remote controller.
The ECONOMY operation is almost the same operation as below settings.
Mode Cooling/ Dry Heating
Target temperature Setting temp.+1°C Setting temp.-1°C
( Table10)