TX200 S6
Options Guide
35
Preparation
4.3.2
Removing system fan 1 (or 1&3)
Ê
Remove system fan 2 (or 2&4) (see
page 34
).
Figure 10: Example: Removing system fan 1&3
Ê
Disconnect the fan cable from the connector FAN1 (if there is a second fan
cable, disconnect this from connector FAN3) on the system board (see the
cabling plans in the Appendix).
Ê
Push the locking lever in the direction of the arrow (1).
Ê
Pull system fan 1 (or 1&3) in the direction of the arrow (2) to disengage the
four hooks.
Ê
Take system fan 1 (or 1&3) out (3).