50
Options Guide
TX200
S6
Processors
6.3
Replacing the heat sink
Ê
Open the server and remove system fan 2 (or 2&4) as described in the
chapter "Preparation" on page 27
.
Ê
Press the heat sink retaining clips downward and inward to release them.
Ê
Swing the heat sink retaining clips up as far as they will go.
Ê
Loosen the heat sink by turning it back and forth and then lift it out.
Ê
Clean the upper side of the processor using a lint-free cloth.
Ê
Remove the protective cover from the new heat sink.
Ê
Mount the heat sink on the processor so that the side with the visible copper
heat pipes is pointing in the direction of the memory slots.
Ê
Fold down the two heat sink retaining clips at the same time and lock the
heat sink by returning the heat sink retaining clips to their original position.
Ê
Reinstall system fan 2 (or 2&4) as described in the
section "Installing system
fan 2 (or 2&4)" on page 108
.
Ê
Close the server, connect it to the power outlet, and switch it on as described
in the
chapter "Completion" on page 107
.
Summary of Contents for PRIMERGY TX200 S6
Page 1: ...Options Guide English PRIMERGY TX200 S6 Server Options Guide Edition November 2011 ...
Page 6: ...OptionsGuide TX200 S6 ...
Page 10: ...OptionsGuide TX200 S6 Contents ...
Page 16: ...16 OptionsGuide TX200 S6 Introduction ...
Page 36: ...36 OptionsGuide TX200 S6 Preparation ...
Page 40: ...40 OptionsGuide TX200 S6 Main memory ...
Page 86: ...86 OptionsGuide TX200 S6 Expansion cards and BBU ...
Page 114: ...114 OptionsGuide TX200 S6 Completion ...
Page 122: ...122 OptionsGuide TX200 S6 Appendix ...
Page 124: ...124 OptionsGuide TX200 S6 Index ...