TX200 S6
Options Guide
31
Preparation
Removing the server from the rack and opening the server
Remove the server from the rack cabinet, if it is not sufficiently accessible.
I
Removing the server from the rack may be different. In this case you will
find the description in the packaging of the rack mounting kit.
Ê
Disconnect all cables on the rear side of the server.
V
CAUTION!
At least two people are needed to lift the server out of the rack cabinet.
Ê
Loosen the two knurled screws on the front (see
figure 4 on page 30
) and
pull the server as far as it will go out of the rack.
Figure 5: Unlocking the server and lifting it out of the rails
Ê
Pull the locking bar forward on both sides (1).
Ê
Lift the server out of the rails (2) and place it on a table, for example.
Ê
Pull the locking lever as far as it will go (see also
figure 2 on page 28
). This
pushes the top cover backward.
Ê
Remove the top cover.
1
0
1
1